MAYCO C-30HDNI PUMP — OPERATION AND PARTS MANUAL — REV. #0 (05/15/03) — PAGE 31
C-30HDNI PUMP — INITIAL START-UP
Starting
1. Turn the throttle control knob fully counter-clockwise to set the
engine speed to IDLE. (Figure 17.)
Figure 17. Throttle Control Knob
2.
Place the pumping control switch (Figure 18) in the OFF
position.
Figure 18. Pumping Control Switch (OFF)
Figure 19. Ignition Switch
3. Insert the ignition key into the ignition switch (Figure 19),
turn the key to the
ON position, then to the START
position, release the key when the engine starts.
NOTE
During
pumping operations, the
engine speed cannot be reduced
below 1300 RPM's. This built in
feature protects the clutch from
disengaging (slipping) during
operation.
DO NOT attempt to operate this concrete
pump until the Safety, General Information
and Inspection sections have been read and
understood.
CAUTION :
System Shut-Down
1. Place the pumping control switch in the OFF position
(Figure 21).
2. Turn the throttle control knob fully counter-clockwise.
Let the engine run at idle speed for 3-5 minutes.
3. Turn the ignition key (Figure 19) to the OFF position.
4. Clean pump as referenced in the maintenance section
of this manual.
7. Let the engine run for 3-5 minutes before putting pump
into operational use.
Push the choke knob in all the way.
8. Listen for any abnormal sounds. If any mechanical or
electrical problems exists, STOP the engine and correct
the problem.
9. To begin pumping concrete. Place the pumping control
switch (Figure 21) in the ON position
Figure 20. Control Box Status Lamps
6. Verify that the
oil pressure, battery and water tem-
perature status lamps (Figure 20) are all OFF. If any of
these lamps are ON, stop the engine and correct the
problem.
Figure 21. Pumping Control Switch (OFF)
Go to Discount-Equipment.com