- Contact the black safety measuring wire with the COM-socket
(black).
- Contact the red safety measuring wire with the V-
socket
(red).
- Bring the black and red measuring tips into contact with the measurement
points. Read the measurement value on the digital display
.
Note:
- In small voltage measuring ranges, the zero-volt indication does not appear
(due to interference) when the safety measuring wires are open. Make sure
that the
MPC2
is fully functional by short-circuiting the measuring
tips.
See fig. 2:
DC-voltage measurement
See fig. 3:
AC-voltage measurement
8.3 Resistance measurement
- Select the desired function with the sliding switch
and the function button
of the
MPC2
.
- Contact the black safety measuring wire with the COM-socket
(black).
- Contact the red safety measuring wire with the V-
socket
(red).
- Bring the black and red measuring tips into contact with the measurement
points. Read the measurement value on the digital display
.
Note:
- To obtain a correct measurement, ensure that no voltage is applied to the
measuring point.
- With small resistances, the measuring result can be improved by measuring
the resistance of the safety measuring wires beforehand by short-circuiting
the measuring tips and subtracting the reading obtained from the resistance
measured.
See fig. 4:
Resistance measurement
8.4 Continuity testing with buzzer
- Select the area marked with the buzzer symbol with the sliding switch
and the function button
of the
MPC2
.
- Contact the black safety measuring wire with the COM-socket
(black).
- Contact the red safety measuring wire with the V-
socket
(red).
- Bring the black and red measuring tips into contact with the measurement
points. If the resistance between the measurement points is less than 50
,
the buzzer incorporated in the
MPC2
sounds.
See fig. 5:
Continuity testing with buzzer
8.5 Current measurement
8.5.1 Preparation for measurement
Store and use the
MPC2
only under the correct temperature
conditions stated. Always avoid long exposure to sunlight.
- Strong sources of interference close to the
MPC2
may produce
unstable readings and measurement errors.
Do not apply voltage to the output contacts of the
03&
.
If necessary, remove the safety measuring wires connected.
When measuring DC current, observe correct polarity.
8.5.2 Current measurement
- Select the desired measuring function with the sliding switch
and the
function button
.
- Press the “ZERO” button to set the
MPC2
to the starting point.
- Operate the opening lever
. Grip the single wire containing the current to
be measured with the prongs of the
MPC2
.
- Read the value in the digital display
.
See fig. 6:
AC/ DC current measurement
9. Maintenance
Before opening the
03&
, ensure that it is not
connected to a source of voltage! Electrical hazard!
Any work required on the
MPC2
when it is under voltage must be
done only by a qualified electrician. Special steps must be taken to prevent
accidents.
Before opening the
MPC2
, remove it from all sources of voltage as
follows:
- Remove first the black and the red measuring tip from the measurement object.