SURGE TEST RESULT
Line to Line 500V and Line to Power Earth 1kV surge test was completed. Input voltage was set at
230Vac/50Hz. Output was loaded at full load and operation was verified following each surge event.
Surge Level (V)
Input Voltage (Vac)
Injection Location
Injection Phase (
ºC
) Test
Result
(Pass/Fail)
±500V
230
L to N
0
Pass
±500V
230
L to N
90
Pass
±500V
230
L to N
180
Pass
±500V
230
L to N
270
Pass
±1000V
230
L to PE
0
Pass
±1000V
230
L to PE
90
Pass
±1000V
230
L to PE
180
Pass
±1000V
230
L to PE
270
Pass
±1000V
230
N to PE
0
Pass
±1000V
230
N to PE
90
Pass
±1000V
230
N to PE
180
Pass
±1000V
230
N to PE
270
Pass