background image

  M4860ADS

MPPT

3

3

0

23 2

5 0

2 05

8 7. 5

Solar Charge Controller

USER MANUAL

Thank you very much for buying our product ,Please read
thoroughly before using the prouuct

Description

 

of

 

Functions

1 . 

Suitable for charging 12V/24V/36V/48V lead-acid batteries, including GEL, Sealed, Flooded battery

2. Mainly suitable for off-grid solar power generation systems, such as: home solar power generation system, solar RV power generation, 
    boat, unattended base stations, outposts and so on. 
3. MPPT charging technology, three-stage charging mode, constant current charge-constant voltage charge-floating charge, 
   effectively improve the battery charging efficiency.  It is more portable than ordinary PWM charging.
4. Suitable for high voltage input, PV voltage up to 150 V (At the lowest temperature -25

). 

5.  input two Channel solar panels at the same time. 
6. This product adopts intelligent single-chip microcomputer design, and all workflows are controlled by software, which can achieve 
     high precision and high reliability. 

7. The charging mode of high-efficiency MPPT is adopted to ensure that the battery works in the best state and greatly prolong the 

    service life of the battery. 
8. It has full automatic control such as overcharge, overdischarge, overload protection, anti-reverse protection and so on

The charge regulator is intended for use in photovoltaic systems with 12V or 24V nominal voltages, It shall be used 
with vented or sealed (VRLA) lead  acid batteries only.
Safety Recommendations:
   1.Batteries store a large amount of energy. Never short circuit a  battery whatever.
   2.Batteries can produce flammable gases. Avoid making sparks, using fire or any naked flame. Make sure that the battery
   room is ventilated.
   3.Avoid touching or short circuiting wires and  terminals. Be aware that the voltages on specific terminals and  wires can
   be up to  double of battery voltage. Use isolated tools. Stand on dry ground and keep your hands dry. 

  

Installation

Attentions

Please  installed in the room, avoiding direct-clearance,
do not install in the wet environment, when use it outdoor, 
please install controller and batteries in the same place, 
and the batteries installed in the same place, the controller

can  measuring the battery temperature, charge 
voltage regulation.
Attention:

1. Screws  specifications M4
2. Make sure heat-location were not l  blocke

Summary of Contents for M4860ADS

Page 1: ...ure that the battery works in the best state and greatly prolong the service life of the battery 8 It has full automatic control such as overcharge overdischarge overload protection anti reverse prote...

Page 2: ...rtight battery where gas may accumulate the place Warning high pressure is dangerous PV arrays may generate high open circuit voltages Disconnect circuit breakers or safety before wiring and be carefu...

Page 3: ...hort circuit in the whole process otherwise it may cause serious safety accidents Connection cable the connection cable between the controller and the battery is as short as possible which can effecti...

Page 4: ...tal stripes rolling up dynamically Load ON Load OFF Press K1 or K2 to cycle forward or backward to browse the current working parameters or set working status Battery voltage PV1 voltage PV2 voltage C...

Page 5: ...rface Browse and press K1 or K2 to cycle to the parameter interface you want to set Short press K3 button SET display SET font flashes to indicate that you can start to change the current parameter pr...

Page 6: ...lashes press K1 or K2 key to change the number of minutes in a cycle 0 59 5 Press the K3 key again the SET and M icons stop flashing the load time is set and save the settings Dual period real time co...

Page 7: ...the battery voltage here otherwise The controller will report an error and the controller will not work Battery voltage Automatic identification Set night detection voltage The night detection voltage...

Page 8: ...or code is displayed and the buzzer alarms synchronously and the alarm continues until the error is corrected Press K4 to exit the wrong generation interface return to the main interface and turn off...

Page 9: ...3 7V Equalization charge 14 6V no 14 8V Boost voltage 0 2V Boost charge 14 4V 14 3V 14 7V 14 15V Float charge 13 5V 13 8V 13 5V 13 14V Boost charge recovery 13 2V Low voltage recovery load output 12 5...

Reviews: