![MPP Solar HYBRID LV 6048 User Manual Download Page 19](http://html1.mh-extra.com/html/mpp-solar/hybrid-lv-6048/hybrid-lv-6048_user-manual_1843971019.webp)
17
13
Setting voltage point back
to battery mode when
selecting “SBU priority” or
“Solar first” in program 01.
Battery fully charged
48.0V
49.0V
50.0V
51.0V
52.0V
53.0V
54.0V
55.0V
56.0V
57.0V
58.0V
16
Charger source priority:
To configure the priority of
charger source
If this inverter/charger is working in Line, Standby or Fault
mode, charger source can be programmed as below:
Solar first
Solar energy will charge battery as
first priority.
Utility will charge battery only when
solar energy is not available.
Utility first
Utility will charge battery as first
priority.
Solar energy will charge battery only
when utility power is not available.
Solar and Utility
Solar energy and utility will charge
battery at the same time.
Only Solar
Solar energy will be the only charger
source no matter utility is available or
not.
If this inverter/charger is working in Battery mode, only solar
energy can charge battery. Solar energy will charge battery if
it's available and sufficient.
18
Alarm control
Alarm on (default)
Alarm off
Summary of Contents for HYBRID LV 6048
Page 1: ...HYBRID LV 6048 INVERTER CHARGER Version 1 0 User Manual...
Page 36: ...34...