16
EN
1.
Use a damp cloth to wipe the fan’s housing and wipe it dry afterwards. Use a mild cleaning
agent for stubborn dirt.
2.
The grates in the intake and exhaust openings can be vacuum-cleaned at low speed. Perform
this cleaning very gently and carefully.
3.
The remote is powered by a CR2025 3V battery. To access the battery, press the interlock’s
embossing (arrow A) and then slide away the battery compartment (arrow B). When inserting
a new battery, make sure the polarity is correct. Once the battery is replaced, slide back the
battery compartment in the device.
CAUTION! Do not discard used batteries with your municipal waste. Only discard them in proper pick-up points
or at the store. Do not place the battery in fire.
Technical data sheet
MPM AGD S.A.
MODEL: MWP-30
Description
Symbol
Value
Unit
Maximum flow rate of the fan
F
15,18
m
3
/min
Fan power
P
41,0
W
Operating value
SV
0,37
(m
3
/min)/W
Power consumption in standby mode
P
SB
0,30
W
Fan’s sound power level
L
WA
57,48
dB(A)
Maximum air speed
c
3,24
m/s
Seasonal electricity consumption
Q
13,46
kWh/a
Standards used for measuring the
operational values
EN IEC 60879:2019
To get additional information, contact
MPM AGD S.A.
ul. Brzozowa 3
Milanówek 05-822, Polska
tel. (22) 380-52-00
BDO: 000027599