16
4. Flow Control
When there is a bulk source or direct head-load of product feeding the Chain-Vey conveyor, the
inlet flow control baffle is very important. The flow control baffle utilizes two plates on a pivot
which increase or decrease the opening of the inlet. Two hand knobs are used to adjust and also
lock the plates' position once the desired feed rate is attained. If desired, a tamper-resistant, tooled
adjustment is an available alternative to the hand knobs.
Note:
To prevent product shear and reduce excessive pull on the chain, the inlet and baffle must be
installed in accordance with the conveying direction as shown above.
Low Fill
(< 50%)
Standard Fill
(70% - 80%)
Maximum Fill
(90%)
To achieve desired fill level, adjust the baffles of the inlet flow control, and make adjustments to
the conveyor speed and feed rate.