Generic Lathe Installation
1. Disconnect hose leading to turret, from low pressure pump, as well as the fitting the hose was
connected to;
2. Install supplied check valve in place of removed fitting;
Arrow pointing towards turret, away from low pressure pump.
3. Install supplied NPTF tee;
4. Install NPT x JIC fitting on side and end of tee;
5. Re-install machine coolant pump fitting that was removed;
Install removed machine tool fitting into open space of supplied check valve.
6. Install supplied high pressure hose to side of tee.
High Pressure In
Low Pressure In
Check Valve
Turret