PRODUCT OVERVIEW
Product Presentation
Filter elements are efficient only if their dirt holding capacity is fully exploited. This is achieved by using filter housings equipped
with DEH Series clogging indicators.
These devices trip when the filter elements become blocked which causes an increase in the pressure drop across the filter.
The indicator is set to alarm before the element becomes fully clogged. This indicator will reduce the frequency of replacing filter
elements as well as maximising the performance of each filter.
• Constructed from AISI 316 stainless steel 420 bar (6,091 PSI)
• 420 bar (6,091 PSI) maximum working pressure
• Approved for use in hazardous environments
• ATEX, IECEX, UL, CSA and TRCU, EAC certified
• Temperature class T4 (135 °C) and T6 (85 °C)
• Protection grade IP66 or IP67 when used with suitable cable gland
• Indication range from 5 bar to 7 bar
• Suitable for use with all MP Filtri stainless steel pressure filters and cast iron pressure filters
Benefits
• Prevents machinery failures
• Cuts unplanned downtime
• Critical early warning system
• Saves time and costs
• Improves safety
Disclaimer
As part of our policy of continual improvement, MP Filtri reserves the right to alter the specification without prior notification.
Area of Application
Hazardous Area Indicators can only be used in the appropriate zone classification.
Ex d indicators should only be used in zones 1 and 2 - zones in which potentially explosive atmospheres created by
gases, vapours or mists are unlikely to occur in normal operation. In the event of an occurence, the situation will persist
for only a short period.
Ex ia indicators can be used in zones 0, 1 and 2. These are suitable in an area where explosive atmospheres are
continually present. For more information please see section 6 - Certification.
• Marine
• Mining
• Petrochemical
• Offshore oil and gas
• Saw mills
• Paper mills
• Car plants
• Industrial plants
• Storage silos
• Hazardous environments
The full range of applications the DEH series is designed for includes: