No LED indicator recognizable
- Cable damage / power breakdown in the
control cable
Generator runs within its working range, however, no function is
recognizable
Fig. 18 | MFA does not function
Only LED 5 (red), „
R.P.M not o.k.
“
The indicators „
R.P.M not ok
“ is lit up and the indicator „
Ready
“ is off
5
Fig. 19 | MFA indicates „R.M.P not ok“
The indicators „
R.P.M not ok
„ and „
Ready
“ are lit up
1
Fig. 20 | MFA indicates a low speed
Display:
Possible cause:
Display:
Possible cause:
- The generator is running too fast
Display:
Possible cause:
Note:
Turn off the engine immediately and have the
speed checked in order to prevent damage to the
generator !
LED 1 (yellow) „
Ready
“
LED 5 (red),
„
R.P.M not o.k
”, possibly
also flashing
The generator is running too slow
Normal magnet operation is only possible to a
limited extent; lower performance is to be expected
LED 5 (permanent), speed 2200 - 2400 rpm
LED 5 (flashing), speed 2400 - 2700 rpm
5
-
www.mozelt.com
CAUTION
Englisch
MOZELT GmbH & Co. KG
Load lifting magnet devices
Technical Manual:
Electrical Power Supply T4002
Copyright:
MOZELT GmbH & Co. KG, D-47269 Duisburg
Edition: May 2012
-13-