3.6
Control cable
Cable for control signals must be shielded. The cable shield must be connected to the connector shell.
The signal ground must not be grounded.
If necessary, please use only original spare parts.
3.7
Terminal Box
Before isolation of power generator and electronics, the following warning should be observed:
The discharge time begins after final shutdown of the power generator!
Fig.: 8 | Connection control line on the power generator
5
1
Magnet connection 230 V DC
2
3
4
5
Protective earth conductor connection
Terminal block
USB connection
Screw terminal control line
Fig.: 7 | Terminal box
Steuerelektronik
1
4
2
3
5
6
6
Control card
WARNING
In the electronics, there are intermediate circuit capacitors.
Their discharge may take longer than 10 minutes!
Before start of work, verify isolation from power supply!
If this is not observed, serious personal injuries with fatal result, severe
injuries to health or considerable damage to property cannot be ruled out!
Fig.: 9 | Terminal block