Moxa Technologies UC-3100 Series Quick Installation Manual Download Page 10

- 10 - 

Accessing the UC-3100 Using a PC 

You can use a PC to access the UC-3100 by one of the following methods: 
A.

 

Through the serial console port with the following settings:   

Baudrate 

= 115200 bps, 

Parity 

= None, 

Data bits 

= 8,   

Stop bits 

= 1, 

Flow Control 

= None

 

 

ATTENTION 

Remember to choose the “VT100” terminal type. Use the console 
cable to connect a PC to the UC-3100's serial console port. 

 

B.

 

Using SSH over the network. Refer to the following IP addresses and 
login information: 

 

Default IP Address 

Netmask 

LAN 1 

192.168.3.127 

255.255.255.0 

LAN 2 

192.168.4.127 

255.255.255.0 

Login: 

moxa

 

Password: 

moxa 

Summary of Contents for UC-3100 Series

Page 1: ...P N 1802031000025 1802031000025 UC 3100 Series Quick Installation Guide Version 4 1 April 2021 Technical Support Contact Information www moxa com support 2021 Moxa Inc All rights reserved...

Page 2: ...nformation Package Checklist Before installing the UC 3100 verify that the package contains the following items 1 x UC 3100 Arm based computer 1 x DIN rail mounting kit preinstalled 1 x Power jack 1 x...

Page 3: ...3 UC 3111...

Page 4: ...4 UC 3121...

Page 5: ...ection has been established Client mode 3 levels with signal strength 1 LED is ON Poor signal quality 2 LEDs are ON Good signal quality All 3 LEDs are ON Excellent signal quality AP mode All 3 LEDs bl...

Page 6: ...operly you will hear a click and the slider will rebound back into place automatically Wall Mounting optional The UC 3100 can also be wall mounted The wall mounting kit needs to be purchased separatel...

Page 7: ...3 pin power terminal block connector when viewed from the angle shown here When you connect to the SG contact the noise will be routed through the PCB and the PCB copper pillar to the metal chassis 2...

Page 8: ...SIM Card Socket The UC 3100 comes with two nano SIM card sockets for cellular communication The nano SIM card sockets are located on the same side as the antenna panel To install the cards remove the...

Page 9: ...unction SD Card Socket The UC 3111 and UC 3121 models come with a SD card socket for storage expansion The SD card socket is located next to the Ethernet port To install the SD card remove the screw a...

Page 10: ...Parity None Data bits 8 Stop bits 1 Flow Control None ATTENTION Remember to choose the VT100 terminal type Use the console cable to connect a PC to the UC 3100 s serial console port B Using SSH over...

Page 11: ...C Sec 501 10 b This product is intended to be supplied by an IEC EN 60950 1 or IEC EN 62368 1 approved power supply suitable for use at 75 C minimum the output of which meets ES1 and PS2 or LPS and th...

Page 12: ...lass I Division 2 Groups A B C and D Special Conditions of Use These devices shall be mounted in a suitable tool accessible ATEX certified enclosure that is rated at least IP54 as defined in EN 60529...