![Moxa Technologies TN-G6512 Serie Quick Installation Manual Download Page 6](http://html1.mh-extra.com/html/moxa-technologies/tn-g6512-serie/tn-g6512-serie_quick-installation-manual_1842671006.webp)
- 6 -
Panel/Wall Mounting
STEP 1: Mounting the TN-G6512 to a wall requires 4 screws. Use the
ToughNet switch as a guide to mark the correct positions of the 4 screws.
STEP 2: Use the 4 screws in the
panel mounting kit. If you would like
to use your own screws, make sure
the screw head is between 6.0 mm
and 7.0 mm in diameter and the
shaft is less than 4.0 mm in
diameter, as shown at the right.
Do not screw the screws in all the way—leave a space of about 2 mm to
allow room for sliding the ToughNet switch between the wall and the
screws.
NOTE Before tightening the screws into the wall, make sure the screw
head and shaft size are suitable by inserting the screw through
one of the keyhole-shaped apertures of the ToughNet switch.
STEP 3: Once the screws are fixed in the wall, hang the ToughNet switch
on the 4 screws through the large opening of the keyhole-shaped
apertures, and then slide the switch downwards. Tighten the four screws
for added stability.
NOTE To provide greater protection from vibration and shock, use
screws with shaft diameter between 6.0 mm and 7.0 mm, and fix
the ToughNet switch onto the wall directly through the large
opening of the keyhole-shaped apertures.
Wiring Requirements
WARNING
Turn the power off before disconnecting modules or wires. The
correct power supply voltage is listed on the product label. Check
the voltage of your power source to make sure you are using the
correct voltage. Do NOT use a voltage greater than what is
specified on the product label.
These devices must be supplied by a SELV source as defined in
the Low Voltage Directive 2006/95/EC and 2004/108/EC.