![Moxa Technologies TN-5308 Installation Manual Download Page 9](http://html1.mh-extra.com/html/moxa-technologies/tn-5308/tn-5308_installation-manual_1842665009.webp)
- 9 -
Connecting the Data Lines
10/100BaseT(X) Ethernet Port Connection
All TN-5308 models have 8 10/100BaseT(X) Ethernet ports (4-pin
shielded M12 connectors with D coding). The 10/100TX ports located on
the TN-5308’s front panel are used to connect to Ethernet-enabled
devices. Most users configure these ports for Auto MDI/MDI-X mode, in
which case the port’s pinouts are adjusted automatically depending on
the type of Ethernet cable used (straight-through or cross-over), and the
type of device (NIC-type or HUB/Switch-type) connected to the port.
In what follows, we give pinouts for both MDI (NIC-type) ports and MDI-X
(HUB/Switch-type) ports. We also give cable wiring diagrams for
straight-through and cross-over Ethernet cables.
Pinouts for the 10/100BaseT(X) Ports on the TN-5308
Pinouts for the RJ45 (8-pin) Port
RJ45 (8-Pin)
MDI Port Pinouts
MDI-X Port Pinouts
Pin Signal
1
Tx +
2
Tx -
3
Rx +
6
Rx -
Pin Signal
1
Rx +
2
Rx -
3
Tx +
6
Tx -
M12 (4-pin, M) to M12 (4-pin, M) Cross-Over Cable Wiring