background image

 

 

P/N: 1802001420642 

*1802001420642* 

TCF-142-RM Series 

Quick Installation Guide 

 

Version 6.0, February 2020 

Technical Support Contact Information 

www.moxa.com/support 

Moxa Americas: 
Toll-free: 1-888-669-2872 
Tel:  1-714-528-6777 
Fax:  1-714-528-6778 

Moxa China (Shanghai office): 
Toll-free: 800-820-5036 
Tel:  +86-21-5258-9955 
Fax:  +86-21-5258-5505 

Moxa Europe: 
Tel:  +49-89-3 70 03 99-0 
Fax:  +49-89-3 70 03 99-99 

Moxa Asia-Pacific: 
Tel:  +886-2-8919-1230 
Fax:  +886-2-8919-1231 

Moxa India: 
Tel:  +91-80-4172-9088 
Fax:  +91-80-4132-1045 

 

 

 

 

 

 

 2020 Moxa Inc. All rights reserved. 

 

 

Summary of Contents for TCF-142-M-SC-RM

Page 1: ...a Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 Moxa India Tel 91 80 4172 9088 Fax 91 80 4132 1045 2020 Moxa Inc All rights reserved ...

Page 2: ...sily for decoding RELIABILITY MAINTENANCE Fiber is immune to adverse temperature and moisture conditions does not corrode or lose its signal and is not affected by short circuits power surges or static electricity No Configuration Required for Baudrate Settings The TCF 142 RM slide in modules work under any baudrate from 50 bps to 921 6 Kbps The TCF 142 RM slide in modules simply convert the signa...

Page 3: ...wise to secure the module to the chassis Features Ring or Point to Point transmission Extend RS 232 422 485 transmission distance up to 40 km with single mode TCF 142 S XX RM slide in modules series up to 5 km with multi mode TCF 142 M XX RM slide in modules series Slide in modules of NRack system Decrease signal interference Protect against electrical degradation and chemical corrosion Support ba...

Page 4: ... 4 Mounting Dimensions Unit mm TCF 142 SC TCF 142 ST ...

Page 5: ...RM slide in modules module series Pin Assignment and Connector 9 pin D sub Female Pin RS 232 RS 422 485 4w RS 485 2w 1 RxD A Data A 2 TxD RxD B Data B 3 RxD TxD B 4 TxD A 5 GND GND GND 6 7 8 9 Fiber Cable SC Port Pinouts SC Port to SC Port Cable Wiring ST Port Pinouts ST Port to ST Port Cable Wiring ATTENTION This is a Class 1 Laser LED product Do not stare into the Laser Beam ...

Page 6: ... OFF ATTENTION For Fiber Ring Users Before you plug the slide in module into the chassis make sure the DIP switch settings are correct before inserting the slide in module into the chassis and connecting the serial and fiber cables If the Rx LEDs of the converter glow continuously remove the fiber cable and reconnect NOTE Ring Mode can only be used for half duplex applications The settings for the...

Page 7: ... data format includes one start bit between five and eight data bits and one stop bit A parity bit and an additional stop bit might be included in the format as well For example 8 N 1 is interpreted as eight data bits no parity bit and one stop bit Users need to adjust the DIP switch to set the data format to 10 bits Baudrate S3 Pin 5 S3 Pin 6 S3 Pin 7 S3 Pin 8 S3 Pin 9 50 OFF ON ON ON ON 75 ON OF...

Page 8: ...ode Multimode 8 3 125 8 7 125 9 125 or 10 125 μm 50 125 62 5 125 or 100 140 μm Wavelength Single mode 1310 nm Multimode 850 nm TX Output Single mode 5 dBm Multimode 5 dBm RX Sensitivity Single mode 25 dBm Multimode 20 dBm Point to Point Transmission Half or Full duplex Multi drop Transmission Half duplex fiber ring Environmental Operating Temperature 0 to 60 C 32 to 142 F 5 to 95 RH Storage Temper...

Page 9: ... 9 3 V m EN 61000 4 8 PFMF EN 61000 4 11 DIPS Free fall IEC 60068 2 32 ...

Reviews: