background image

 

 

P/N: 1802001016015 

*1802001016015* 

PTC-101 

Quick Installation Guide 

Moxa Industrial Media Converter 

Edition 5.1, November 2017 

Technical Support Contact Information 

www.moxa.com/support 

Moxa Americas: 
Toll-free: 1-888-669-2872 
Tel:  1-714-528-6777 
Fax:  1-714-528-6778 

Moxa China (Shanghai office): 
Toll-free: 800-820-5036 
Tel:  +86-21-5258-9955 
Fax:  +86-21-5258-5505 

Moxa Europe: 
Tel:  +49-89-3 70 03 99-0 
Fax:  +49-89-3 70 03 99-99 

Moxa Asia-Pacific: 
Tel:  +886-2-8919-1230 
Fax:  +886-2-8919-1231 

Moxa India: 
Tel:  +91-80-4172-9088 
Fax:  +91-80-4132-1045 

 

 

 

 

 

 

 2017 Moxa Inc. All rights reserved. 

 

 

Summary of Contents for PTC-101 Series

Page 1: ...upport Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70...

Page 2: ...101 perfect for ensuring that your Ethernet equipment can withstand critical industrial applications such as in hazardous locations and complies with FCC UL and CE standards Package Checklist The PTC...

Page 3: ...nal block for power input 3 Heat dissipation vents and relay output 4 DIP switch 5 Power input PWR LED 6 Fiber Link Active LED 7 100BaseFX Port ST SC LC connector 8 10 100BaseT X 9 TP port 10 Mbps LED...

Page 4: ...ions for the PTC 101 S SC other models available by request Wiring Requirements ATTENTION Safety First Be sure to disconnect the power cord before installing and or wiring your Moxa Industrial Media C...

Page 5: ...eparate The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together Keep input wiring and output wiring separated We strongly advise labeling wiring to all...

Page 6: ...erminal block receptor which is located on the PTC 101 LV s top panel ATTENTION Before connecting the PTC 101 LV to the DC power inputs make sure the DC power source voltage is stable Communication Co...

Page 7: ...sed to transmit data from device I to device II and the other optical line is used transmit data from device II to device I for full duplex transmission All you need to remember is to connect the Tx t...

Page 8: ...tion is disabled ON Forces the Ethernet port to use Full Duplex OFF Forces the Ethernet port to use Half Duplex 4 Link Fault Pass Through Enable Disable ON Enables Link Fault Pass Through The link sta...

Page 9: ...port 10 Mbps link is inactive 100M Green On Ethernet port 100 Mbps is active Blinking Data is being transmitted at 100 Mbps Off Ethernet port 100 Mbps link is inactive Specifications Technology Standa...

Page 10: ...A protects against two signals shorted together Reverse Polarity Protection Present Physical Characteristics Housing Aluminum IP30 protection Dimensions W x H x D 122 5 x 90 x 20 mm 4 82 x 3 54 x 0 7...

Reviews: