LED Indicators 

System LEDs 

LED 

Color 

State 

Description 

On 

System has passed self-diagnosis 
test on boot-up and is ready to run. 

GREEN 

Blinking  System is undergoing the 

self-diagnosis test. 

STAT 

RED 

On 

System failed self-diagnosis on 
boot-up. 

On 

Power is being supplied to the main 
module’s power input PWR1. 

PWR1 AMBER 

Off 

Power is not being supplied to the 
main module’s power input PWR1. 

On 

Power is being supplied to the main 
module’s power input PWR2. 

PWR2 AMBER 

Off 

Power is not being supplied to the 
main module’s power input PWR2. 

On 

The corresponding PORT alarm is 
enabled and a user-configured 
event has been triggered. 

FAULT RED 

Off 

The corresponding PORT alarm is 
enabled and a user-configured 
event has not been triggered, or 
the corresponding PORT alarm is 
disabled. 

On 

This PT switch is set as the Master 
of the Turbo Ring, or as the Head of 
the Turbo Chain. 

Blinking  The PT switch has become the Ring 

Master of the Turbo Ring, or the 
Head of the Turbo Chain, after the 
Turbo Ring or the Turbo Chain went 
down. 

MSTR/HEAD GREEN 

Off 

The PT switch is not the Maste
this Turbo Ring or is set as a 

r of 

Member of the Turbo Chain. 

On 

The PT switch coupling function is 
enabled to form a back-up path, or 
it is set as the Tail of the Turbo 
Chain. 

Blinking  Turbo Chain is down. 

CPLR/TAIL GREEN 

Off 

This PT switch disabled the coupling 
function, or is set as a Member of 
the Turbo Chain. 

 
 
 
 
 
 
 
 
 

- 6 - 

Summary of Contents for PowerTrans PT-7728-PTP

Page 1: ...2010 Moxa Inc All rights reserved Reproduction without permission is prohibited P N 1802077280030 PT 7728 PTP Hardware Installation Guide Moxa PowerTrans Switch First Edition August 2010...

Page 2: ...2 rack mount ears Panel Layout M3 M4 4 3 M1 M2 Front view Front Cabling Front view Rear Cabling Rear view Front Cabling Rear view Rear Cabling 7 8 M4 M3 M2 M1 PT 7728 PTP CONSOLE 1 2 3 4 1 2 1 2 3 4 1...

Page 3: ...PM 7200 4SSC2TX 96 8 96 8 96 8 PM 7200 6MSC PM 7200 6SSC PM 7200 2MSC4TX PM 7200 2SSC4TX PM 7200 4MST2TX 96 8 96 8 96 8 PM 7200 6MST PM 7200 2MST4TX PM 7200 1MST6TX 40 7 40 7 40 7 40 7 40 7 40 7 40 7...

Page 4: ...wire and common wire Observe all electrical codes dictating the maximum current allowable for each wire size If the current goes above the maximum ratings the wiring could overheat causing serious dam...

Page 5: ...Y circuit will be closed Wiring the Redundant Power Inputs Each PT switch has two sets of power inputs power input 1 and power input 2 STEP 1 Insert the dual set positive negative DC wires into PWR1 a...

Page 6: ...nfigured event has been triggered FAULT RED Off The corresponding PORT alarm is enabled and a user configured event has not been triggered or the corresponding PORT alarm is disabled On This PT switch...

Page 7: ...g or chain port of this PT switch RING CHAIN PORT GREEN Off The corresponding module s port is not the ring or chain port of this PT switch On The corresponding module s port is the coupler port of th...

Page 8: ...eristics Housing IP 30 protection metal case Dimensi W x H x ons D mm 17 32 x 1 73 x 12 76 in 440 x 44 x 325 Weight 5900 g Installation 19 rack mounting Regulatory Approvals Safety UL60950 1 CSA C22 2...

Reviews: