background image

OnCell G3100 Series User’s Manual 

Edition 10.0, January 2018 

www.moxa.com/product 

 

© 2018 Moxa Inc. All rights reserved. 

 

 

Summary of Contents for OnCell G3110

Page 1: ...OnCell G3100 Series User s Manual Edition 10 0 January 2018 www moxa com product 2018 Moxa Inc All rights reserved...

Page 2: ...to this manual or to the products and or the programs described in this manual at any time Information provided in this manual is intended to be accurate and reliable However Moxa assumes no responsi...

Page 3: ...onsole 3 7 4 Introducing Serial Port Operation Modes 4 1 Overview 4 2 Device Control Applications 4 2 Real COM and Secure Real COM Modes 4 2 Types of Real COM Connection 4 3 Reverse Real COM and Secur...

Page 4: ...ost via Cellular 9 3 10 Configuring Virtual Modem Mode 10 1 OnCell G3100 Web Settings 10 2 Installing Windows Driver Manager 10 2 Using Windows Driver Manager 10 5 Using PComm for Data Transmission 10...

Page 5: ...k Connections 13 20 Network Statistics 13 20 Routing 13 20 DHCP Client List 13 21 Internet Sessions List 13 21 Save Configuration 13 22 Restart 13 22 Restart System 13 22 Restart Ports 13 22 14 Softwa...

Page 6: ...B RFC2217 B 1 C Dynamic Domain Name Server C 1 Overview C 1 Configuration C 2 D Well Known Port Numbers D 1 E Auto IP Report Protocol E 1 F GSM Alphabet F 1 G Default Settings G 1...

Page 7: ...d cellular standard and serial interface type For example OnCell G3110 is a GRPS IP gateway with RS 232 serial interface while OnCell G3150 HSPA is a HSPA IP gateway with RS 232 422 485 serial interfa...

Page 8: ...The OnCell G3100 provides a powerful function to ensure that serial data is buffered in case of a communication failure When a communication failure occurs the serial data is buffered in the OnCell G3...

Page 9: ...rs for status and signal level 2 digital inputs and 1 relay output GuaranLink for reliable connection Remote command by SMS Product Specifications Note The OnCell G3100 series has several hardware rev...

Page 10: ...ls RS 232 TxD RxD RTS CTS DTR DSR DCD GND RS 422 Tx Tx Rx Rx GND RS 485 4w Tx Tx Rx Rx GND RS 485 2w Data Data GND I O Interface Alarm Contact 1 relay output with current carrying capacity of 1A 24 VD...

Page 11: ...against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may ca...

Page 12: ...equipment should be installed and operated with a minimum distance of 20 cm between the radiator your body This device complies with Part 15 of the FCC Rules Operation is subject to the following two...

Page 13: ...pics are covered in this chapter Panel Layout Connecting the Hardware Wiring Requirements SIM Card Installation Connecting the Power Connecting the I O Port Connecting to the Network Connecting to a S...

Page 14: ...OnCell G3100 Series Getting Started 2 2 Panel Layout Front View OnCell G3110 G3150 OnCell G3110 HSPA G3150 HSPA Top View Bottom Views For RS 232 models For RS 232 422 485 models...

Page 15: ...G3100 cellular IP gateway to a host PC or serial Ethernet devices for first time testing purposes We cover topics such as Wiring Requirements SIM Installation DIN Rail Mounting Connecting the Power Co...

Page 16: ...OTE Do not run signal or communication wiring and power wiring in the same wire conduit To avoid interference wires with different signal characteristics should be routed separately Use the type of si...

Page 17: ...s stored on the SIM card if the PIN code cannot be accessed then the IP gateway will not be accessible over the network Connecting the Power The dual power inputs that connect to the 4 pin power termi...

Page 18: ...he bottom panel and one RS 422 RS 485 4w RS 485 2w that connects through a 5 pin terminal block on the bottom panel Connecting to the Ethernet Device Connect one end of the Ethernet cable to the OnCel...

Page 19: ...t setting To set the termination resistor to 1 K make sure both of the assigned DIP switches are in the ON position ATTENTION Do not use the 1 K setting on the OnCell when using the RS 232 interface D...

Page 20: ...n Booting up or IP fault Blinking slowly 1 sec Cannot get an IP address from the DHCP server off Power is off or there is no error condition Signal 3 LEDs Green Signal Level at least 2 LEDs must illum...

Page 21: ...ously for 5 sec to load factory defaults Use a pointed object such as a straightened paper clip or toothpick to press the reset button This will cause the Ready LED to blink on and off The factory def...

Page 22: ...chapter introduces the different methods that can be used Please refer to Chapter 14 System Management Settings for more details about network settings The following topics are covered in this chapte...

Page 23: ...re referred to as private IP addresses Devices configured with a private IP address are not directly accessible from a public network For example you would not be able to ping a device with a private...

Page 24: ...address for your OnCell G3100 from your network administrator 2 Obtain your OnCell G3100 s MAC address from the label on the bottom panel 3 Execute the arp s command from your computer s MS DOS promp...

Page 25: ...t from the default setting use your IP address instead Click OK 2 The console terminal type selection is displayed as shown Enter 1 for ansi vt100 and then press ENTER to continue 3 The following page...

Page 26: ...BACKSPACE or SPACE keys to erase the current IP address and then type in the new IP address and press ENTER Note that if you are using a dynamic IP configuration BOOTP DHCP etc you will need to go to...

Page 27: ...se the arrow keys to select Save and then press ENTER Press ENTER again to confirm the save command 10 Press R or use the arrow keys to select Restart and then press ENTER 11 Press S or use the arrow...

Page 28: ...to connect the OnCell G3100 s serial console port to your computer s RS 232 serial port 2 From the Windows desktop select Start All Programs PComm Lite Terminal Emulator 3 The PComm Terminal Emulator...

Page 29: ...or if password protection was not enabled you will be prompted to select the terminal mode Press 1 for ansi vt100 and then press ENTER 8 The main menu should appear Once you are in the console you ma...

Page 30: ...ode please refer to Chapter 6 Using the Web Console for detailed information on configuration parameters The following topics are covered in this chapter Overview Device Control Applications Real COM...

Page 31: ...uter supports the TCP IP protocol you will not be limited by the host computer s bus limitation such as ISA or PCI nor will you be limited if you do not have drivers for various operating systems In a...

Page 32: ...llular network unpacks the TCP IP packet and then transparently sends the data through the serial port to the attached serial device Types of Real COM Connection This section illustrates the types of...

Page 33: ...x64 2003 x86 x64 Vista x86 x64 and 2008 x86 x64 Reverse Real COM mode uses a mechanism similar to port mapping to enable your remote device that is using a private IP address to remain accessible to...

Page 34: ...OnCell G3100 s serial port Please refer to Appendix B for more information Socket Applications The OnCell G3100 offers the following modes for socket applications TCP Server and Secure TCP Server TCP...

Page 35: ...ssage sent from the OnCell G3100 Please refer to Appendix E for the format of the Auto IP Report Protocol Domain name with DDNS If your cellular service provider offers a public IP address after you c...

Page 36: ...data encryption using SSL Types of TCP Client Connection TCP Client to PC s IP address The OnCell G3100 will only be able to connect to a host PC if the PC is using a public IP address TCP Client to P...

Page 37: ...the OnCell G3100 from a host PC that has a fixed public IP Domain name with DDNS If your cellular service provider assigns a public IP address after you connect to the cellular network you can also ac...

Page 38: ...ssage on a highway display panel place refill orders for vending machines handle maintenance for remote rental equipment or even help create an SMS alarm by directly transforming text binary or unicod...

Page 39: ...00 The OnCell G3100 not only connects serial devices to cellular networks but Ethernet devices as well After selecting the proper operation mode please refer to Chapters 9 10 11 and 13 for detailed in...

Page 40: ...each other over the pre established connection This software can be installed by a customer or hosted by Moxa for demonstration or testing purposes only and can be accessed from anywhere across an IP...

Page 41: ...is technique can allow an external user to reach a port on a private IP address inside a LAN from the outside via a NAT enabled IP gateway OnCell G3100 s NAT original is enabled Cellular Enabling Ethe...

Page 42: ...cabling distance between computers and modems Figure 1 The setup in Figure 2 is not an efficient architecture because we need to deploy extra devices to bridge the gap A more efficient solution is pr...

Page 43: ...options The same configuration options are also available through the Telnet and serial console The following topics are covered in this chapter Using Your Web Browser Browser Cookie Settings Trusted...

Page 44: ...enable cookies by selecting Internet Options from the Tools menu 2 Select the Privacy tab There are six levels of privacy setting Block All Cookies High Medium High Medium Low and Accept All Cookies U...

Page 45: ...o modify the list of trusted sites You may also access the list of trusted sites directly through Internet Options in the Tools menu of Internet Explorer Select the Security tab click on the Trusted S...

Page 46: ...irections Please refer to Chapter 3 Initial IP Address Configuration for details on how to configure the IP address Enter the console password if prompted This will not apply if you did not enable pas...

Page 47: ...ous settings and categories When you click on a menu item in the navigation panel the main window will display the corresponding options for that item Configuration changes can then be made in the mai...

Page 48: ...time first select the correct time zone and submit the change The console will display the real time according to the time zone To modify the real time clock click on Modify next to the Local time fie...

Page 49: ...ell G3100 is configured with the correct time server address it will request time information from the time server every 10 minutes Network Settings Basic Network Settings You can access Basic Network...

Page 50: ...Usually the computers that control traffic within the network or at the local Internet service provider are gateway nodes The OnCell G3100 needs to know the IP address of the default gateway computer...

Page 51: ...to identify Internet domain names and translate the names into IP addresses A domain name is an alphanumeric name such as www moxa com that it is usually easier to remember than the numeric IP address...

Page 52: ...in case the dynamic IP has changed The parameters shown below are used to configure the Auto IP report function There are two ways to develop an Auto IP report Server to receive the OnCell s Auto IP...

Page 53: ...for establishing connection with the ISP If GuaranLink determines that the OnCell cannot establish a connection with the ISP it reboots the OnCell in order to allow the OnCell to retry the connection...

Page 54: ...on Cellular connection alive check retry count default 3 sec This setting specifies the number of attempts to reach the remote target s before the OnCell re establishes a connection Packet level conne...

Page 55: ...options discussed here are also available from the Telnet and serial consoles The following topics are covered in this chapter GSM GPRS Settings For OnCell G3110 and G3150 Cellular Setting OnCell G311...

Page 56: ...hone must be used to change the PIN Selecting the Radio Band Although GSM 900 and GSM 1800 are used in most parts of the world operators in United States Canada and many other countries in the America...

Page 57: ...ervices only when receiving a request from a remote PC Destination IP address Source IP address IP netmask If you do not configure these three parameters they will be filled in automatically by the re...

Page 58: ...the Ethernet every 3 seconds after powering on After failing to connect 5 times in a row the data from the serial device will be sent through the GSM connection When the remote Ethernet host returns t...

Page 59: ...to connect to UMTS HSPA first then GPRS after powering on Inactivity time is up Trunk Remote host fail remote host recovered Remote Ethernet host has failed The OnCell G3100 will keep pinging the rem...

Page 60: ...7 6 Virtual Modem Operation mode Virtual Modem mode only available for OnCell G3110 G3150 is designed for AT command operating system devices For more details please refer to Chapter 5 for an introduc...

Page 61: ...he individual serial port modes The following topics are covered in this chapter Port Setting Basics Device Control Applications Real COM Mode Reverse Real COM Mode RFC2217 Mode Socket Applications TC...

Page 62: ...he navigation panel Operation Modes Communication Parameters and Data Buffering Log Select Operation Modes in the navigation panel to select and configure the mode for each serial port Application Sel...

Page 63: ...application the OnCell G3100 will use the serial communication parameters as defined here in the web console and all hosts connected to the port must use identical serial settings If one of the hosts...

Page 64: ...be transmitted after 1 additional byte is received following the delimiter Delimiter 2 Data in the buffer will be transmitted after 2 additional bytes are received following the delimiter Strip Delimi...

Page 65: ...ted and one or more of the hosts stops responding as the port is transmitting data If you select Disable the port will wait until the data has been transmitted successfully to all hosts before transmi...

Page 66: ...ular or Ethernet connection status to affect the RTS or DTR signals Packet length default 0 The Packet length setting refers to the maximum amount of data that is allowed to accumulate in the serial p...

Page 67: ...one character is 10 bits 1200 bits s 1000 ms s 8 3 ms Therefore you should set the force transmit time to be greater than 8 3 ms so in this case it must be greater than or equal to 10 ms If it is nece...

Page 68: ...ted after 1 additional byte is received following the delimiter Delimiter 2 Data in the buffer will be transmitted after 2 additional bytes are received following the delimiter Strip Delimiter Data in...

Page 69: ...ive packets ATTENTION You should make sure the inactivity time value used here is less than the inactivity time value on the GSM GPRS configuration page The GSM GPRS connection must be maintained in o...

Page 70: ...he host In order to prevent a TCP port conflict with other applications the user can set the Command port to another port if needed Packet length default 0 The Packet length setting refers to the maxi...

Page 71: ...transmit time depends on your application but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bi...

Page 72: ...ng disconnected it is highly recommended that this value is set large enough so that the intended data transfer is completed ATTENTION Inactivity time is ONLY active when Connection Control see below...

Page 73: ...imiter 1 is enabled the serial port will clear the buffer and send the data to the Ethernet port when a specific character entered in hex format is received A second delimiter character may be enabled...

Page 74: ...In UDP mode you may specify up to 4 ranges of IP addresses for the serial port to connect to At least one destination range must be provided ATTENTION The maximum selectable IP address range is 64 add...

Page 75: ...limiter before being transmitted Force transmit default 0 ms This parameter defines how large a gap in serial communication the OnCell G3100 will allow before packing the serial data in its internal b...

Page 76: ...e remote Ethernet modem or host The OnCell G3100 s response depends on the ATS0 value as follows ATS0 0 The OnCell G3100 will temporarily accept the TCP connection and then send the RING signal out th...

Page 77: ...ion reply OK only 7 ATM Speaker control option reply OK only 8 ATO On line command 9 ATP ATT Set Pulse Tone Dialing mode reply OK only 10 ATQ0 ATQ1 Quiet command default ATQ0 11 ATSr n Change the cont...

Page 78: ...Backspace character default 8 ASCII 7 S6 Wait time for dial tone always 2 unit sec no action applied 8 S7 Wait time for carrier default 3 unit sec 9 S8 Pause time for dial delay always 2 unit sec no a...

Page 79: ...is specified data in the buffer will be sent as soon it reaches the specified length Delimiter 1 and Delimiter 2 default None When Delimiter 1 is enabled the serial port will queue the data in the bu...

Page 80: ...pplication but it must be at least larger than one character interval within the specified baudrate For example assume that the serial port is set to 1200 bps 8 data bits 1 stop bit and no parity In t...

Page 81: ...Cellular Enabling Ethernet Device In this chapter we explain how to configure the Cellular enabling Ethernet device The following topics are covered in this chapter Host to OnCell via Cellular OnCell...

Page 82: ...an make some of the LAN computers accessible from the Internet by enabling Virtual Server Depending on the requested service the OnCell redirects the external service request to the appropriate server...

Page 83: ...he Ethernet device acts as the Client In order for the Ethernet device to send data to the host it must set the OnCell as a gateway This function will automatically detect the OnCell s IP address by D...

Page 84: ...because different cellular services have different software installation methods Note This function is only supported by the OnCell G3100 Rev 2 0 and Rev 3 0 Please refer to the Specifications section...

Page 85: ...n items are described below Installing Windows Driver Manager Windows Driver Manager should be installed for all cellular connections 1 Download Windows Driver Manager from www moxa com and then click...

Page 86: ...l Modem Mode 10 3 3 Click Next to install program files to the default directory or click Browse to select an alternate location 4 The Setup window will display a summary of the installation options C...

Page 87: ...change the installation settings click Back and navigate to the previous screen On Windows XP the installer will display a message that the software has not passed Windows Logo testing as shown below...

Page 88: ...ur PC host Make sure that the serial port s on your OnCell G3100 are set to Real COM mode when mapping COM ports with Windows Driver Manager 1 Go to Start Windows Driver Manager Windows Driver Manager...

Page 89: ...lick No to activate the COM ports later Using PComm for Data Transmission The following instructions and screenshots show how to data transmit using PComm Terminal Emulator which is available free of...

Page 90: ...n Parameter tab and then select the appropriate COM port for the connection COM8 in this example Configure the parameters for 115200 8 N 1 115200 for Baudrate 8 for Data Bits None for Parity and 1 for...

Page 91: ...ceiver answering a dial in SMS via AT command Example of a user sending a message Receiver getting a message Set 7 bits ASCII Send my message to Phone No Enter SMS text and Press Ctrl Z here to Send A...

Page 92: ...via AT command You can connect to the Internet GPRS via AT command There are two commands you need to know APN AT CGDCONT 1 IP APN Dial ATD 99 1 GPRS via Windows Dial up Network 1 Go to Start Settings...

Page 93: ...Checkmark the box for Don t detect my modem I will select it from a list Click Next to continue 4 When the Add Hardware Wizard page appears select Have Disk 5 Browse the Windows Driver Manager folder...

Page 94: ...GPRS model has been added to the list Select it and then click Next 7 Click on Selected ports This COM port needs to be the COM port number mapped by Windows Driver Manager not necessarily COM 1 Choos...

Page 95: ...To change the installation settings click Back and navigate to the previous screen In Windows XP Setup will display the following message indicating that the software has not passed Windows Logo testi...

Page 96: ...nd Modem Options page will show up Select and double click on the modem attached to the COM port not necessarily COM 1 mapped by Window Driver Manager 11 Click on the Advanced tab Under Extra initiali...

Page 97: ...es Configuring Virtual Modem Mode 10 14 12 Click OK to close the page The COM port number will be whichever one was mapped by Windows Driver Manager 13 Go to Start Settings Network Connections Create...

Page 98: ...OnCell G3100 Series Configuring Virtual Modem Mode 10 15 14 Click on Next 15 Select Connect to the Internet and then click Next...

Page 99: ...OnCell G3100 Series Configuring Virtual Modem Mode 10 16 16 Select Set up my connection manually and then click Next 17 Create your own ISP name...

Page 100: ...Virtual Modem Mode 10 17 18 You must enter 99 1 as a phone number and click Next 19 Type the Internet Account Information The information must match ISP Settings Click Next to continue 20 Click Finish...

Page 101: ...OnCell G3100 Series Configuring Virtual Modem Mode 10 18 21 Click Dial to connect to a cellular network...

Page 102: ...this chapter What Are VPNs OnCell VPN Specifications OnCell VPN Web Console Settings Manual Key ESP Configuration Remote Network Local Network Incoming Security Settings Outgoing Security Settings IS...

Page 103: ...VPN client can initiate a connection with a VPN server Once the connection is established cellular devices can communicate with other network devices on the same private network OnCell VPN Specificati...

Page 104: ...uration VPN tunnel default Disable Enable or disable the VPN tunnel function VPN tunnel mode The type of VPN tunnel policy to be used either manual key IPsec or ISAKMP with Pre shared Keys PSK Remote...

Page 105: ...16 AES 192bit 24 AES 256bit 32 Authentication mode Select the incoming authentication mode Authentication key Enter the incoming authentication key Authentication mode Length Bytes MD5 16 SHA1 20 Outg...

Page 106: ...he type of VPN tunnel policy to be used either manual key IPsec or ISAKMP with Pre shared Keys PSK Remote Network Remote endpoint IP or hostname Enter the WAN IP or hostname of the remote VPN server e...

Page 107: ...the DH Group number increases the higher the level of encryption implemented for PFS SA life time default 86400 Enter the number of seconds for the VPN ISAKMP phase 1 Lifetime This is the period of t...

Page 108: ...t VPN tunnel start phase 1 main mode connect VPN start phase1 aggr mode connect VPN tunnel start phase1 aggressive mode connect VPN start encryption VPN tunnel start encryption VPN phase1 pass VPN tun...

Page 109: ...l serial port settings for the OnCell G3100 The same configuration options are also available through the Telnet and serial consoles The following topics are covered in this chapter Port Communication...

Page 110: ...closest supported baudrate The margin for error will be less than 1 7 for all baudrates under 921600 bps Data bits default 8 This field configures the data bits parameter Note If data bits is set to 5...

Page 111: ...e TCP Server TCP Client Secure TCP Client and SMS Tunnel modes For other modes the port buffering settings will have no effect Port buffering default Disable You may enable port buffering by setting t...

Page 112: ...ettings E mail Alert SNMP Trap SMS Alert Maintenance Console Setting Ping Manual SMS Firmware Upgrade Configuration Import Export Load Factory Defaults Change Password Remote SMS Control Certificate E...

Page 113: ...allow access to a specific IP address Enter the IP address in the corresponding field enter 255 255 255 255 for the netmask To allow access to hosts on a specific subnet For both the IP address and n...

Page 114: ...y and Read Write Access Control The following fields allow you to define user names passwords and authentication parameters for two levels of access read only and read write The name of the field will...

Page 115: ...r OnCell G3100 Host Table The Host Table can be used to simplify IP address entry in the OnCell G3100 console by assigning a Host Name to a Host IP Address When you assign a Host Name to a Host IP Add...

Page 116: ...ummary For example if System was enabled then System Cold Start events and System Warm Start events would be logged Group Event System System Cold Start System Warm Start Power 1 DOWN Power 2 DOWN Cel...

Page 117: ...sible from the Internet by enabling Virtual Server Depending on the requested service the OnCell redirects the external service request to the appropriate server within the LAN network The OnCell is a...

Page 118: ...ngs configure the OnCell to change the status of the relay output and SMS if the specified connection goes down Console web text login auth fail This field refers to a failed attempt to log in to a pa...

Page 119: ...to low it indicates that the connection line is down When the DCD signal changes to low the OnCell G3100 will automatically send a warning to the administrator as configured on the Serial Event Setti...

Page 120: ...ail server This field is for your mail server s domain name or IP address User name This field is for your mail server s user name if required Password This field is for your mail server s password if...

Page 121: ...automatic warnings message will be sent Encode format SMS Data Format Text ASCII 7 bits default 7 bits text format 160 bytes per packet Customized SMS Customized SMS Settings default Disable Enable th...

Page 122: ...rs Auth type You can restrict the access by enabling the Caller ID under Auth Type Caller ID Enter Caller ID number so that only SMS from specific senders can trigger Remote SMS control restart When r...

Page 123: ...e After the SMS is sent the UI will show the entry number the time it was sent the destination phone number and whether the SMS was successfully sent or not Remote Caller ID Remote Caller ID can be us...

Page 124: ...n this chapter for more information on passwords Finally you may also enable or disable the reset button Always Enable default Always functional Disable after 60 secs The reset button will not work af...

Page 125: ...iguration Import Export The OnCell G3100 can share or back up its configuration by exporting all settings to an encrypted file To import a configuration go to System Management Maintenance Configurati...

Page 126: ...set up a new password or change the existing password enter your desired password under both New password and Confirm password To remove password protection leave the New password and Confirm password...

Page 127: ...ell G3100 series will generate a new SSL certificate whenever a new IP is used However the SSL certificate is issued by the OnCell itself If you would like to import an SSL certificate issued by a pri...

Page 128: ...active and a gray dot indicates inactive Serial Port Error Count Go to Serial Port Error Count under Serial Status to view the error count for each serial port Serial Port Settings Go to Serial Port...

Page 129: ...ASCII or HEX format After selecting the serial port and format you may click Select all to select the entire log if you wish to copy and paste the contents into a text file System Log This option disp...

Page 130: ...Management You may click Dout State under System Status to display a list of events that may cause a change to the Dout state If a configured alarm event occurs the Dout state changes and you may come...

Page 131: ...twork Connections Go to Network Connections under System Status to view network connection information Network Statistics Go to Network Statistics under System Status to view network statistics Routin...

Page 132: ...List shows all the clients that require and have successfully received IP assignments Check the Refresh box to refresh the list Internet Sessions List The Internet Sessions page displays full details...

Page 133: ...If you do not save your changes before restarting they will be discarded Restart Restart System Go to Restart System under Restart and then click Restart to restart the OnCell G3100 Ensure that you sa...

Page 134: ...Driver Manager OnCell Search Utility Installing OnCell Search Utility Configuring OnCell Search Utility Moxa OnCell Linux Real TTY Driver Basic Procedure Hardware Setup Installing Linux Real TTY Driv...

Page 135: ...OnCell G3100 serial ports that are set to Real COM mode The software manages the installation of drivers that allow you to map unused COM ports on your PC to serial ports on the OnCell G3100 These dri...

Page 136: ...program files to the default directory or click Browse to select an alternate location 3 Click Next to install the program s shortcuts in the appropriate Start Menu folder 4 Click Next to proceed with...

Page 137: ...e installation To change the installation settings click Back and navigate to the previous screen On Windows XP the installer will display a message that the software has not passed Windows Logo testi...

Page 138: ...our PC host Make sure that the serial port s on your OnCell G3100 are set to Real COM mode when mapping COM ports with Windows Driver Manager 1 Go to Start Windows Driver Manager Windows Driver Manage...

Page 139: ...o Click OK to proceed to the next step Note that the Add OnCell page supports FQDN Fully Qualified Domain Name in which case the IP address will be filled in automatically If you select WAN IP or Host...

Page 140: ...f the OnCell G3100 is changed For information on the Auto IP Report function please refer chapter 6 4 COM ports and their mappings will appear in blue until they are activated Activating the COM ports...

Page 141: ...ation 14 8 5 When using Windows XP a message is displayed during the activation of each port indicating that the software has not passed Windows Logo certification Click Continue Anyway to proceed 6 P...

Page 142: ...you can select Input Manually and then manually enter the LAN MAC address for OnCell G3100 Click OK to proceed to the next step To re configure the settings for a particular serial port on the OnCell...

Page 143: ...etting tab to modify Tx Mode FIFO Fast Flush and other parameters Tx Mode Hi Performance is the default for Tx mode After the driver sends data to the OnCell G3100 the driver immediately issues a Tx E...

Page 144: ...in the OnCell firmware buffer rather than just flushing the local buffer This design is used to satisfy some special considerations However it may take more time about several hundred milliseconds th...

Page 145: ...on to enable data to be encrypted when transmitted over the COM ports After selecting the encryption option select the Keep connection option to start encrypting COM port communications immediately wi...

Page 146: ...le to another host and use the same COM Mapping settings in the other host OnCell Search Utility Installing OnCell Search Utility 1 Download Windows Driver Manager from www moxa com and then click the...

Page 147: ...3 Click Next to install program files to the default directory or click Browse to select an alternate location 4 Click Next to select additional tasks 5 Click Next to proceed with the installation The...

Page 148: ...ch Utility The Broadcast Search function is used to locate all OnCell G3100 servers that are connected to the same LAN as your computer After locating an OnCell G3100 you will be able to change its IP...

Page 149: ...Software Installation Configuration 14 16 2 When the search is complete all OnCell G3100 servers that were located will be displayed in the OnCell Search Utility window Click Locate to cause the sele...

Page 150: ...l G3100 click on the Console icon to open the web console This will take you to the web console where you can make all configuration changes Please refer to Chapter 6 Using the Web Console for informa...

Page 151: ...to Chapter 6 Using the Web Console for information on how to use the IP Address Report Moxa OnCell Linux Real TTY Driver Basic Procedure To map an OnCell G3100 serial port to a Linux host s tty port...

Page 152: ...oncell_realtty driver folder mxaddsvr Add Server mapping tty port mxdelsvr Delete Server un mapping tty port mxloadsvr Reload Server mxmknod Create device node tty port mxrmnod Remove device node tty...

Page 153: ...is not provided in the command line the program will list the installed servers and total ports on the screen You will need to choose a server from the list for deletion Removing Linux Driver Files A...

Page 154: ...the same directory that contains the program oncellttyd You may use vi or any text editor to modify the file as follows ttyp1 192 168 1 1 950 For more configuration information view the file oncelltt...

Page 155: ...o modify the file For more configuration information look at the file oncellttyd cf which contains detailed descriptions of the various configuration parameters 2 Find the process ID PID of the progra...

Page 156: ...topics are covered in this appendix Port Pinout Diagrams RS 232 male DB9 Pinouts 4W 2W RS 485 RS 422 Terminal Block Pinouts Power Input and Relay Output Pinouts Cable Wiring Diagrams Serial Cables Pi...

Page 157: ...Terminal Block Pinouts PIN RS 422 RS 485 4W RS 485 2W 1 TxD B 2 TxD A 3 RxD B Data B 4 RxD A Data A 5 GND GND Power Input and Relay Output Pinouts PIN Name Function 1 V1 DC Power Input 1 2 V1 DC Powe...

Page 158: ...OnCell G3100 Series Pinouts and Cable Wiring A 3 Cable Wiring Diagrams Serial Cables Female DB9 to Male DB9 Female DB9 to Male DB25...

Page 159: ...iring A 4 Pin Assignments for DB9 and DB25 Connectors Pin Assignments for DB9 Male and Female Connectors DB9 Male Connector DB9 Female Connector Pin Assignments for DB25 Male and Female Connectors DB2...

Page 160: ...mode as RFC2217 mode By default the first serial port on the OnCell G3100 is assigned TCP port 4001 the second serial port is assigned TCP port 4002 and so on 2 Download and install a third party driv...

Page 161: ...its desired server name OC3100 in the illustration according to the option 12 standard 2 The DHCP server replies with the IP address that is assigned to the OnCell G3100 along with the domain name mo...

Page 162: ...dns com Configuration DDNS default Disable Use this field to enable or disable DDNS Server address default DynDns org Currently DynDns org is the only option available for Server address Host name In...

Page 163: ...n most systems can only be used by system processes or by programs executed by privileged users The following table shows famous port numbers among the listed well known port numbers For more details...

Page 164: ...42 Host name server names server 43 Whois nickname 49 Login Host Protocol login 53 Domain Name Server domain 69 Trivial Transfer Protocol TETP 70 Gopher Protocol 79 Finger Protocol 80 World Wide Web...

Page 165: ...In order to know what IP address the OnCell is using you need to set up parameters in Network Settings via Web browser The figure below is the OnCell Web console configuration window Enter the IP add...

Page 166: ...Value Description Length Note 11 Signal Level 1 Unsigned char 12 RSSI 1 Unsigned char AP ID Hardware ID Mapping Table AP ID Hardware ID Product 0x80003501 0x3512 G3110 0x80003501 0x3552 G3150 0x80003...

Page 167: ...Name Character ISO 8859 1 DEC 0x00 0 COMMERCIAL AT 64 0x01 1 POUND SIGN 163 0x02 2 DOLLAR SIGN 36 0x03 3 YEN SIGN 165 0x04 4 LATIN SMALL LETTER E WITH GRAVE 232 0x05 5 LATIN SMALL LETTER E WITH ACUTE...

Page 168: ...AMPERSAND 38 0x27 39 APOSTROPHE 39 0x28 40 LEFT PARENTHESIS 40 0x29 41 RIGHT PARENTHESIS 41 0x2A 42 ASTERISK 42 0x2B 43 PLUS SIGN 43 0x2C 44 COMMA 44 0x2D 45 HYPHEN MINUS 45 0x2E 46 FULL STOP 46 0x2F...

Page 169: ...TH TILDE 209 0x5E 94 LATIN CPAITAL LETTER U WITH DIAERESIS 220 0x5F 95 SECTION SIGN 167 0x60 96 INVERTED QUESTION MARK 191 0x61 97 LATIN SMALL LETTER A A 97 0x62 98 LATIN SMALL LETTER B B 98 0x63 99 L...

Page 170: ...Hex Dec Character Name Character ISO 8859 1 DEC 0x7C 124 LATIN SMALL LETTER O WITH DIAERESIS 246 0x7D 125 LATIN SMALL LETTER N WITH TILDE 241 0x7E 126 LATIN SMALL LETTER U WITH DIAERESIS 252 0x7F 127...

Page 171: ...e Inactivity Time 0 Link quality report Disable Connection Control Always On None Connection Interval 5 min GPRS Operation Mode TCP IP Compression Disable Inactivity Time 0 Link quality report Disable...

Page 172: ...th 0 Delimiter process Do Nothing Force transmit 0 TCP Client Mode TCP port 4001 Designated Port 5010 to 5013 TCP alive Check Time 7 Inactivity time 0 Ignore jammed IP Disable Secure Disable Connectio...

Page 173: ...Settings Virtual Server Disable OnCell Central Server Server Disable Management information port 63201 Management configuration port 63202 Telnet port 63203 OP mode data port 1 63211 OP mode cmd port...

Reviews: