NE-4100 Series User’s Manual
Web Console Configuration
6-17
ATTENTION
Up to 4 connections can be established between the module and hosts. The connection speed or
throughput may be low if one of the four connections is slow. In this case, the other 3
connections will be delayed while waiting for the slowest connection to finish transmitting or
receiving.
ATTENTION
The
Destination IP address
parameter can accept domain names address in place of IP
addresses if a DNS server has been configured. For some applications, you may need to send the
data actively to a remote destination’s domain name address.
TCP connect on
Setting
Factory Default
Necessity
Start up,
Any Character
Start up
Optional
Start up:
The module will attempt to establish a TCP connection as soon as it is powered on.
Any Character:
The module will attempt to establish a TCP connection as soon as the module
starts receiving serial data.
UDP Mode
NOTE:
“Serial Command Mode” is supported in firmware version 3.0 and above.
Delimiter 1
Setting
Factory Default
Necessity
00 to FF
“0” for None
Optional
Delimiter 2
Setting
Factory Default
Necessity
00 to FF
“0” for None
Optional