Panel Mounting 
The MD-219 comes with 14 optional clamp mounts for installation 
on a wall (where space has been cut out to accommodate the rest 
of the hardware) or into computing stations where a flush mount is 
desired. The maximum thickness of the surface to which the 
display will be clamped is 11 mm.
 For a secure mounting, all 14 
clamps must be used. The clamp arms are fastened into slots on all 
four sides of the MD-219. Use the short M4 SUS screws to fasten 
the clamp arms to the MD-219 mounting slots, as shown in the 
magnified inset in the diagram just below. Next, use the clamps to 
fasten the display to its mounting point; note the torque value 
shown in the figure inset below. 

 

VESA Mounting 
The MD-219 also comes with an optional VESA mounting kit. Six 
flat screws and four round screws are required to fasten the VESA 
mounting bracket. See the figure below for detailed screw 
specifications and torque values. 

 

An additional four screws (not included in the kit) are required to 
mount the display on a VESA rack. For this purpose, use M6 screws 
with a length between 10 and 12 mm. 

Connector Description 

Extending the Display 
The MD-219 comes with both standard VGA and DVI-D interfaces 
on the bottom panel. It will automatically detect whether the input 
video source is from the VGA or DVI-D interface. 
Configuring the Display via the Serial Port 
The MD-219 has two serial ports. The RS-232 port uses a DB9 
connector, and the RS-422/485 port uses a terminal block 
connector. Either serial port can be used to modify the display 
parameters using UART commands. Refer to the MD-219 User’s 
Manual for serial port configuration details. The pin assignments 
for the ports are shown in the following table: 

Pin  RS-232 

DCD 

RxD 

TxD 

DTR 

GND 

DSR 

RTS 

CTS 

 

 

 

Pin  RS-422  RS-485 (2-wire) 

RxDB(+)  TDp(+) 

RxDA(-)  TDn(-) 

TxDB(+)  RDp(+) 

TxDA(-)  RDn(-) 

GND 

GND 

 

 

Powering on/off the MD-219 

To power on the MD-219, connect to an AC power source, a DC 
power source, or both. Touch the MENU button for 1 second to turn 
on the display. Touch the MENU button for 4 seconds to turn off the 
display. 

 

NOTE  If only one power input is being connected, the INFO button 

will be red. This will not affect the functionality and 
performance of MD-219 as long as the power input is 
stable.

 

 

 

Grounding the MD-219 Series 
Proper grounding and wire routing help to limit the effects of noise 
from electromagnetic interference (EMI). Run the ground 
connection from the ground screw to the grounding surface prior to 
connecting the power source. 