background image

- 7 - 

NOTE 

A 4 mm

conductor must be used when the connection to the 

external grounding screw is utilized. The heat sink is grounded 
to the chassis by an internal screw. 

 

Terminal Block 

Terminal block (J1)—R/C (XCFR2, XCFR8), socket soldered on to the 
PWB, DINKLE ENTERPRISE CO., LTD, type 5EHDRM, rated 300 V, 15 A, 
105°C. The terminal block is suitable for connecting to plug type 
5ESDVM rated 300 V, 15 A, 105°C. The plug-half connection is secured 
by screws; suitable for 12 to 28 AWG wire size, secured on plug by 
screws with a torque value of 0.51 N-m (4.5 lb-in). 

Ethernet Ports 

The 10/100/1000 Mbps Ethernet ports use RJ45 connectors. 

Pin 

10/100 Mbps 

1000 Mbps 

ETx+ 

TRD(0)+ 

ETx- 

TRD(0)- 

ERx+ 

TRD(1)+ 

– 

TRD(2)+ 

– 

TRD(2)- 

ERx- 

TRD(1)- 

– 

TRD(3)+ 

– 

TRD(3)- 

 

 

Serial Ports 

The serial ports use DB9 connectors. Each port can be configured by 
software as a RS-232, RS-422, or RS-485 port. The pin assignments for 
the ports are shown below: 

Pin  RS-232 

RS-422 

RS-485 

(4-wire) 

RS-485 

(2-wire) 

DCD 

TxDA(-) 

TxDA(-) 

– 

RxD 

TxDB(+)  TxDB(+) 

– 

TxD 

RxDB(+)  RxDB(+)  DataB(+) 

DTR 

RxDA(-) 

RxDA(-)  DataA(-) 

GND 

GND 

GND 

GND 

DSR 

– 

– 

– 

RTS 

– 

– 

– 

CTS 

– 

– 

– 

 

 

USIM Slot 

The MC-3201-TGLX-S model has four USIM slots for 5G/LTE wireless 
Internet connections. Each slot supports four USIM cards. To install a 
USIM card, gently remove the outer cover on the front panel, and then 
insert the USIM card into the slot. 

USB Hosts 

The MC-3201 has 2 USB 3.0 and 4 USB 2.0 Type-A connectors located 
on the front panel. The ports support keyboard and mouse devices and 
can also be used to connect a flash disk for storing large amounts of 
data. 

Display Connectors 

The MC-3201 has two DisplayPort connectors located on the rear panel, 
allowing users to connect to audio or video devices.   

Summary of Contents for MC-3201 Series

Page 1: ...P N 1802032010010 1802032010010 MC 3201 Series Quick Installation Guide Version 1 0 July 2022 Technical Support Contact Information www moxa com support 2022 Moxa Inc All rights reserved ...

Page 2: ... SSD expansion modules With compliance with the IEC 60945 and E10 standards the MC 3201 is sure to deliver stable and reliable system operation for marine and IIoT applications These certifications are issued to products to indicate their suitability for marine applications to allow them to be used in potentially hazardous environments Package Checklist Before installing the MC 3201 verify that th...

Page 3: ... 3 Rear Panel MC 3201 TGL1 Front Panel Rear Panel ...

Page 4: ...w Blinking Data transmission Off No data transmission LAN 1 2 3 4 on connectors Green Steady On 100 Mbps Ethernet link Blinking Data is being transmitted Yellow Steady On 1000 Mbps Ethernet link Blinking Data is being transmitted Off 10 Mbps Ethernet link or LAN is not connected Tx 1 2 serial ports Green Blinking Data is being transmitted Off No connection Rx 1 2 serial ports Yellow Blinking Data ...

Page 5: ...i 90D Nylok STEP 2 Use two screws per bracket to attach the MC 3201 to a wall or cabinet Note Mounting the MC 3201 to a wall requires four screws Use the MC 3201 computer with the wall mounting brackets attached as a guide to mark the correct locations of the screws on the wall The heads of the screws should be at least 6 0 mm in diameter the shafts should be 3 5 mm in diameter with a minimum dept...

Page 6: ...nnected to an outlet with an earthing connection ATTENTION The equipment MC 3201 TGL7 M S is intended to be supplied by the external power source UL listed IEC 60950 1 IEC 62368 1 which output complies with ES1 SELV output rating is 24 VDC 2 7 A min an ambient temperature 55 C minimum ATTENTION The equipment MC 3201 TGL1 S S is intended to be supplied by the external power source UL listed IEC 609...

Page 7: ...Ports The serial ports use DB9 connectors Each port can be configured by software as a RS 232 RS 422 or RS 485 port The pin assignments for the ports are shown below Pin RS 232 RS 422 RS 485 4 wire RS 485 2 wire 1 DCD TxDA TxDA 2 RxD TxDB TxDB 3 TxD RxDB RxDB DataB 4 DTR RxDA RxDA DataA 5 GND GND GND GND 6 DSR 7 RTS 8 CTS USIM Slot The MC 3201 TGLX S model has four USIM slots for 5G LTE wireless I...

Page 8: ...ate drive NOTE The storage disk should be installed and maintained by a skilled person To install a storage disk do the following Step 1 Unfasten two screws and remove the storage cover on the front panel of the MC 3201 Step 2 Slide the latch on the disk tray to the left and pull out the tray from the slot Step 3 Place the storage disk onto the tray Step 4 Fasten the four screws on the back of the...

Page 9: ...C 3201 Ensure that you insert the tray into the plastic rails on both sides of the slot Step 6 Pull the latch on the tray to the right to secure the tray in the slot Step 7 Put back the cover on the storage slot and fasten the two screws to secure the cover in place ...

Reviews: