1.

 

Connect the incoming cable to the ISD surge protector. 

2.

 

Connect the outgoing cable to ISD surge protector. 

3.

 

Connect the outgoing cable to external device. 

4.

 

Attach the DIN rail attachment plate to the ISD surge protector. 

5.

 

Power on the external device or equipment. 

 

 

PIN 

RS-422/485-4W 

RS-485-2W 

TxD-(A) 

– 

TxD-(B) 

– 

RxD-(B) 

Data+(B) 

RxD-(A) 

Data-(A) 

Shielded GND 

Shielded GND 

Suitable Applications 

ISD-1110/1130-T 

The ISD-1110-T and ISD-1130-T are suitable for general purpose 
applications, such as: 

 

Engines 

 

Low power motors (below 4 kW) 

 

Low voltage power systems 

ISD-1210/1230-T 

The ISD-1210-T and ISD-1230-T are suitable for harsh environment 
applications, such as: 

 

Outdoor applications 

 

Building entryways 

 

High voltage power systems 

 

High power motors (over 4 kW) 

 

Critical applications 

 

Expensive equipment 

Summary of Contents for ISD-1100 Series

Page 1: ...2013 Moxa Inc All rights reserved P N 1802011003010 ISD 1100 1200 T Series Hardware Installation Guide Data Line Surge Protector First Edition January 2013...

Page 2: ...erial data line surge protector is shipped with the following items 1 surge protector Hardware installation guide printed Warranty card Note If any of these items is missing or damaged please contact...

Page 3: ...own in the figures below STEP 1 Insert the top of the DIN rail into the slot just below the stiff metal spring STEP 2 The DIN rail attachment unit will snap into place as shown below To remove the ISD...

Page 4: ...otector 2 Connect the outgoing cable to ISD surge protector 3 Connect the outgoing cable to the external device 4 Power on the external device or equipment PIN RS 422 485 4W RS 485 2W 1 TxD A 2 TxD B...

Page 5: ...nnect the outgoing cable to ISD surge protector 3 Connect the outgoing cable to the external device 4 Attach the DIN rail attachment plate to the ISD surge protector 5 Power on the external device or...

Page 6: ...85 2W 1 TxD A 2 TxD B 3 RxD B Data B 4 RxD A Data A 5 Shielded GND Shielded GND Suitable Applications ISD 1110 1130 T The ISD 1110 T and ISD 1130 T are suitable for general purpose applications such a...

Page 7: ...7 Circuit Design ISD 1110 T ISD 1130 T ISD 1210 T...

Page 8: ...out all of the above please contact Moxa Technical Support Existing Installations 1 Check to see if your equipment is turned on 2 Inspect all connections 3 Remove and bypass all protection devices on...

Page 9: ...n Mode Line to line line to ground Protection Rating IP30 Bandwidth 10 MHz loss 1 dB Connectors ISD 1110 T Data in DB9 male Data out DB9 female ISD 1130 T Data in Terminal block Data out Terminal bloc...

Page 10: ...p www moxa com warranty Note ISD products will only be repaired once within 5 years of purchase After the first repair the product s warranty will no longer be valid RMA Policy Moxa does not provide R...