background image

 

 

P/N: 1802045300003 

*1802045300003* 

ioThinx 4530 Series 

Quick Installation Guide 

 

Version 1.2, December 2019 

Technical Support Contact Information 

www.moxa.com/support

 

Moxa Americas: 
Toll-free: 1-888-669-2872 
Tel:  1-714-528-6777 
Fax:  1-714-528-6778 

Moxa China (Shanghai office): 
Toll-free: 800-820-5036 
Tel:  +86-21-5258-9955 
Fax:  +86-21-5258-5505 

Moxa Europe: 
Tel:  +49-89-3 70 03 99-0 
Fax:  +49-89-3 70 03 99-99 

Moxa Asia-Pacific: 
Tel:  +886-2-8919-1230 
Fax:  +886-2-8919-1231 

Moxa India: 
Tel:  +91-80-4172-9088 
Fax:  +91-80-4132-1045 

 

 

 

 

 

 

 2019 Moxa Inc. All rights reserved. 

 

 

Summary of Contents for ioThinx 4530 Series

Page 1: ...xa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 Moxa India Tel 91 80 4172 9088 Fax 91 80 4132 1045 2019 Moxa Inc All rights reserved ...

Page 2: ...fied by the manufacturer the protection provided by the equipment may be impaired The manufacturer is not responsible for accidents caused by improper use of the equipment Appearance ioThinx 4533 Package Checklist 1 x ioThinx 4530 Series product 1 x quick installation guide printed 2 x side cover plate Installation Connecting the System Power Connect your 12 to 48 VDC power source to the SP and SP...

Page 3: ...unding connectors will contact the DIN rail when the product is attached to it Connecting the Field Power The ioThinx 4530 Series can receive field power through a 12 24 VDC power input Field power can be used to supply power for some types of I O modules such as digital input and analog output modules ...

Page 4: ...ection to the unit Serial Communication The ioThinx 4530 Series is equipped with a 3 in 1 serial interface that supports either 1 RS 232 port 1 RS 422 port or 2 RS 485 ports Refer to the pin assignment table below for details PIN RS 232 P1 RS 422 P1 RS 485 P1 P2 1 TXD TXD DATA 1 2 RXD TXD DATA 1 3 RTS RXD DATA 2 4 CTS RXD DATA 2 5 GND GND GND 45M Module Wiring For more detailed information about 4...

Page 5: ... of the unit onto the DIN rail and then rotate the unit downwards until the bottom mounting clip comes in contact with the DIN rail Step 2 Push the unit towards the DIN rail until the mounting clip snaps into place Installing a 45M Module on a DIN Rail Step 1 Align the 45M module side by side with the head CPU module making sure that the upper and lower rails are hooked together ...

Page 6: ...e internal bus will be established Removing a 45M Module from a DIN Rail WARNING Be sure the power is off before removing modules to avoid damaging the equipment Step 1 Use your finger to lift the release tab on the lower part of the module Step 2 Push the top of the release tab to latch it and then pull the module out NOTE Electrical connections for the internal bus will be disconnected when the ...

Page 7: ...ion Before installing the device make sure there is enough space between the device and nearby items walls other devices etc to ensure proper heat dissipation To ensure that the device works properly we suggest reserving at least 30 mm of space on each of the four sides as shown in the figure CAUTION Do not install the device vertically If the device is installed vertically the fanless heat dissip...

Page 8: ...linking Data is being transmitted Off Inactive Connecting to the ioThinx 4530 Series Controller Use the following configuration information to log in to the ioThinx 4530 Series controller Port Default IP Subnet Mask LAN1 192 168 127 254 255 255 255 0 LAN2 192 168 126 254 255 255 255 0 Username moxa Password moxa NOTE Be sure to configure the host PC s IP address to use the same subnet as the unit ...

Page 9: ...rom the drop down box or type the model name in the search box In the following screenshot the ioLogik E1200 Series is used to illustrate Step 3 Go to the Software Documentation page to download the latest software for the product Specifications Input Current System Power 1 94 A Max Field Power 2 A Max Input Voltage System Power 12 to 48 VDC Field Power 12 24 VDC Operating Temperature Standard Mod...

Page 10: ...3 Cables rated for a minimum temperature of 105 C must be used for the Power Supply Terminal 4 We suggest using the following cable types for wiring ioThinx 4530 Series AWG 12 to 16 for power connections AWG 16 to 28 for serial connections AWG 12 to 18 for field power ground connections 45MR 7210 AWG 12 to 16 for power connections 45MR 2600 2601 2606 Digital Output Terminals AWG 16 to 18 45MR 2404...