Moxa Technologies IEX-402-SHDSL Series Quick Installation Manual Download Page 11

- 11 - 

LED Indicators 

LED 

Color 

State  Description 

PWR1 

AMBER 

On 

Power is being supplied to the power 
input PWR1 

Off 

Power is not being supplied to the power 
input PWR1 

PWR2 

AMBER 

On 

Power is being supplied to the power 
input PWR2 

Off 

Power is not being supplied to the power 
input PWR2 

STATE 

GREEN 

On 

System has passed self-diagnosis test 
on boot-up and is ready to run 

Blinking 

1.

 

System is undergoing the 
self-diagnosis test when booting up. 

2.

 

Blinks continuously when pressing 
the reset button 5 seconds to reset 
to factory default. 

RED 

On 

1.

 

System failed self-diagnosis on 
boot-up. 

2.

 

Link Fault Pass Through active, link 
fault on the opposite unit 

Blinking 

Link Fault Pass Through active, link fault 
on this unit 

FAULT 

RED 

On 

System is in the event of failure, or is 
under quick inspection 

Off 

System is in normal operation 

10/100M 
(TP port) 

GREEN 

On 

The corresponding port’s link is active 

Blinking 

The corresponding port’s data is being 
transmitted 

Off 

The corresponding port’s link is inactive 

LINK/ACT 

GREEN 

On 

The corresponding port’s link is active at 
Turbo speed 

Blinking 

The corresponding port is auto 
negotiating for the optimized speed 
(Blink every 1 sec) 
The corresponding port’s data is being 
transmitted 

Off 

The corresponding port’s link is inactive 

AMBER 

On 

The corresponding port’s link is active at 
Standard speed 

Blinking 

The corresponding port is auto 
negotiating for the optimized speed   
(Blink every 1 sec) 
The corresponding port’s data is being 
transmitted   

Off 

The corresponding port’s link is inactive 

CO/CPE 

GREEN 

On 

The IEX-402 is set as CPE 

Off 

The corresponding port’s link is inactive 

AMBER 

On 

The IEX-402 is set as CO 

Off 

The corresponding port’s link is inactive 

Summary of Contents for IEX-402-SHDSL Series

Page 1: ...3 1802004020013 IEX 402 SHDSL Series Quick Installation Guide Moxa Managed SHDSL Ethernet Extender Version 2 2 January 2021 Technical Support Contact Information www moxa com support 2021 Moxa Inc All...

Page 2: ...orks The IEX 402 SHDSL series has a wide operating temperature range of 40 to 75 C and supports 12 24 48 VDC redundant power supplies The rugged hardware design makes the IEX 402 SHDSL Series perfect...

Page 3: ...State LED 4 Fault LED 5 10 100BaseT X Port 6 DSL speed SNR LED 7 Detachable 2 contact DSL Port 8 Link ACT LED 9 TP port s 10 100 Mbps LED 10 DSL Port RJ 45 RJ 11 connector 11 CO CPE LED 12 Model name...

Page 4: ...4 Mounting Dimensions unit mm inches...

Page 5: ...et Extender from the DIN Rail simply reverse Steps 1 and 2 Wall Mounting optional For some applications you will find it convenient to mount the IEX 402 SHDSL on the wall as shown in the following fig...

Page 6: ...overheat causing serious damage to your equipment Be sure to read and follow these important guidelines Use separate paths to route wiring for power and devices If power wiring and device wiring paths...

Page 7: ...ing the IEX 402 SHDSL to the DC power inputs make sure the DC power source voltage is stable Auto MDI MDI X Connection The Auto MDI MDI X function allows users to connect the IEX 402 SHDSL s 10 100Bas...

Page 8: ...Signal 1 2 3 4 Ring 5 Tip 6 7 8 Wiring the 2 Contact DSL Port The 2 contact terminal block connectors on the IEX s top panel are used for the IEX s DSL port wiring Top and front views of the terminal...

Page 9: ...diagrams to connect the IEX 402 SHDSL s console port to your PC s COM port You may then use console terminal software such as Moxa PComm Terminal Emulator to access the IEX 402 SHDSL S serial console...

Page 10: ...red as a CO and the other as a CPE By factory default IEX 402 SHDSL are configured as COs To make configuration easier the IEX 402 SHDSL supports CO CPE auto negotiation Enable the factory setting CO...

Page 11: ...vent of failure or is under quick inspection Off System is in normal operation 10 100M TP port GREEN On The corresponding port s link is active Blinking The corresponding port s data is being transmit...

Page 12: ...ow control back pressure flow control Interface RJ45 Port 10 100BaseT X auto negotiation speed F H duplex mode and auto MDI MDI X connection DSL Port RJ 11 RJ 45 connector or detachable 2 contact term...

Page 13: ...Subpart B Class A CISPR EN 55032 class A EMS EN 61000 4 2 ESD Level 3 EN 61000 4 3 RS Level 3 EN 61000 4 4 EFT Level 3 EN 61000 4 5 Surge Level 3 EN 61000 4 6 CS Level 3 EN 61000 4 8 Shock IEC 60068...