background image

 

- 3 - 

Panel Views of EDS-P510A-8PoE 

Front Panel View

 

 

 

Top Panel View 

 

 

Rear Panel View 

   

 

 

1.

 

Power input PWR1 LED 

2.

 

Power input PWR2 LED 

3.

 

Fault LED 

4.

 

MSTR/HEAD LED 

5.

 

CPLR/TAIL LED 

6.

 

1000Mbps copper port of the 
combo port 

7.

 

100/1000Mbps SFP port of the 
combo port 

8.

 

Gigabit port speed LED 

9.

 

Model name 

10.

 

SmartPoE LED indicator of PoE+ 
ports 

11.

 

Fast Ethernet port speed LED 

12.

 

10/100Mbps IEEE 802.3af/at 
port 

13.

 

Terminal block for digital input 

14.

 

Terminal block for relay output 

15.

 

RS-232 serial console port 

16.

 

DIP switches 

17.

 

Grounding screw 

18.

 

Terminal block for power input 1 

19.

 

Terminal block for power input 2 

20.

 

Screw holes for wall mounting kit 

21.

 

DIN rail mounting kit 

22.

 

Heat dissipation vents 

 
 

Summary of Contents for EtherDevice EDS-P510A-8PoE Series

Page 1: ...2013 Moxa Inc All rights reserved P N 1802005100020 Moxa EtherDeviceTM Switch EDS P510A 8PoE Series Hardware Installation Guide First Edition January 2013...

Page 2: ...th high EMI immunity The Ethernet switches support a variety of management functions including STP RSTP TurboRing Turbo Chain PoE power management PoE device auto checking PoE power scheduling IGMP VL...

Page 3: ...o port 8 Gigabit port speed LED 9 Model name 10 SmartPoE LED indicator of PoE ports 11 Fast Ethernet port speed LED 12 10 100Mbps IEEE 802 3af at port 13 Terminal block for digital input 14 Terminal b...

Page 4: ...he DIN Rail attachment plate to the EDS P510A 8PoE make sure the stiff metal spring is situated towards the top as shown by the following figures STEP 1 Insert the top of the DIN Rail into the slot ju...

Page 5: ...of the screws should be less than 6 0 mm in diameter and the shafts should be less than 3 5 mm in diameter as shown in the figure on at right NOTE Before tightening the screws into the wall make sure...

Page 6: ...alculate the maximum possible current in each power wire and common wire Observe all electrical codes dictating the maximum current allowable for each wire size If the current goes above the maximum r...

Page 7: ...ct FAULT The relay contacts of the 2 pin terminal block connector are used to detect user configured events The two wires attached to the fault contacts form an open circuit when a user configured eve...

Page 8: ...g protocol was developed by Moxa to provide better network reliability and faster recovery time Moxa Turbo Ring s recovery time is less than 300 ms Turbo Ring or 20 ms Turbo Ring V2 compared to a 3 to...

Page 9: ...ust enable the Turbo Ring function first before using the DIP switch to activate the Master and Coupler functions NOTE If you do not enable any of the EDS P510A 8PoE switches to be the Ring Master the...

Page 10: ...nking Data is being transmitted at 10 Mbps Off TP port s 10 Mbps link is inactive Port 1 to Port 8 100M GREEN On TP port s 100 Mbps link is active Blinking Data is being transmitted at 100 Mbps Off TP...

Page 11: ...up 1 2 3 9 Flow Control IEEE 802 3x flow control back pressure flow control Switch Properties Priority Queues 4 Max Number of Available VLANs 64 VLAN ID Range VID 1 to 4094 IGMP Groups 256 Interface R...

Page 12: ...00 M higher altitude available on demand Regulatory Approvals Safety UL508 Traffic Control NEMA TS2 Railway EN 50121 4 EMI FCC Part 15 CISPR EN55022 class A EMS EN61000 4 2 ESD Level 3 EN61000 4 3 RS...

Reviews: