10/100BaseT(X) Ethernet Port Connection 

The 10/100BaseT(X) ports located on EDS-726’s front panel are used to 
connect to Ethernet-enabled devices. 
Below we show pinouts for both MDI (NIC-type) ports and MDI-X 
(HUB/Switch-type) ports. 

MDI Port Pinouts 

MDI-X Port Pinouts

8-pin RJ45 

 

 Pin  Signal 

Pin  Signal

 1 

Tx+ 

1  Rx+ 

 2 

Tx- 

2  Rx- 

 3  Rx+ 

3  Tx+ 

 6 

Rx- 

Tx- 

 

 

1000BaseT Ethernet Port Connection

 

1000BaseT data is transmitted on differential TRD+/- signal pairs over copper 
wires. 

MDI/MDI-X Port Pinouts 

Pin Signal 

1 TRD(0)+ 
2 TRD(0)- 
3 TRD(1)+ 
4 TRD(2)+ 
5 TRD(2)- 
6 TRD(1)- 
7 TRD(3)+ 
8 TRD(3)- 

1

                                                        

8

 

 

100/1000BaseFX Ethernet Port Connection 

The concept behind the SC/ST port and cable is quite straightforward. Suppose 
you are connecting devices I and II. Contrary to electrical signals, optical 
signals do not require a circuit in order to transmit data. Consequently, one of 
the optical lines is used to transmit data from device I to device II, and the 
other optical line is used to transmit data from device II to device I, for 
full-duplex transmission. 
All you need to remember is to connect the Tx (transmit) port of device I to the 
Rx (receive) port of device II, and the Rx (receive) port of device I to the Tx 
(transmit) port of device II. If you make your own cable, we suggest labeling 
the two sides of the same line with the same letter (A-to-A and B-to-B, as 
shown below, or A1-to-A2 and B1-to-B2). 

SC-Port Pinouts

 

SC-Port to SC-Port Cable Wiring

 

Tx

Rx

 

A

A

B

B

Cable Wiring

 

 

                       A

 

 

                       B

 

 
 

1

                                                        

8

Summary of Contents for EDS-726 Series

Page 1: ...Moxa EtherDevice Switch EDS 726 Hardware Installation Guide Second Edition June 2008 2008 Moxa Inc all rights reserved Reproduction without permission is prohibited P N 1802007260011...

Page 2: ...ULT MASTER PWR2 LNK ACT SPEED IM 1GSXSC IM 1GTX IM 4MSC TX RX 3 4 TX RX 1 2 PWR P3 P1 P4 P2 IM 4MST TX RX 3 4 TX RX 1 2 PWR P3 P1 P4 P2 3 4 IM 4TX 1 2 PWR P3 P1 P4 P2 RS 232 Console Load Save CF 1 2 5...

Page 3: ...or 2 power inputs 2 DIs and 2 DOs 6 Save and load buttons for CF card 7 Serial Console port 8 CF card socket 9 Gigabit Ethernet Module LEDs 10 Two cartridge receptors for Gigabit Ethernet Interface Mo...

Page 4: ...View EtherDevice Switch EDS 726 106 63 149 15 362 40 401 00 Rear View 128 00 146 47 140 00 Side View Gigabit Ethernet Interface Modules Front View Side View 101 20 95 60 59 00 66 20 66 20 24 Fast Eth...

Page 5: ...om the DIN Rail The DIN Rail attachment plates have an internal spring that keeps the attachment plate pushed upwards DIN Rail DIN Rail brace Wall Mounting optional For some applications you will find...

Page 6: ...oxa EDS 726 Calculate the maximum possible current in each power wire and common wire Observe all electrical codes dictating the maximum current allowable for each wire size If the current goes above...

Page 7: ...the terminal block connector to the terminal block receptor RELAY1 RELAY2 PWR1 PWR2 V2 V2 V1 V1 DI1 I1 I2 DI2 Top View Front View FAULT The two sets of relay contacts of the 6 pin terminal block conn...

Page 8: ...rts on EDS 726 connect to other devices Pinouts are diagrams that indicate the type of signal passing through each of the port s pins NOTE 1 The pin numbers for male DB9 and DB25 connectors and hole n...

Page 9: ...he SC ST port and cable is quite straightforward Suppose you are connecting devices I and II Contrary to electrical signals optical signals do not require a circuit in order to transmit data Consequen...

Page 10: ...input PWR1 PWR1 AMBER Off Power is not being supplied to the main module s power input PWR1 On Power is being supplied to the main module s power input PWR2 PWR2 AMBER Off Power is not being supplied...

Page 11: ...rt s data is not being transmitted On The corresponding module s port is the ring port of this EDS 726 RING PORT GREEN Off The corresponding module s port is not the ring port of this EDS 726 On The c...

Page 12: ...6 slots for any combination of 4 port Interface Modules with 10 100BaseT X or 100BaseFX Gigabit Ethernet 2 sockets for any combination of 1 port Interface Modules with 10 100 1000BaseT X 1000BaseSX 10...

Page 13: ...port SC connector IM 1GLXSC Interface Module with 1 1000BaseLX port SC connector IM 1GLHXSC Interface Module with 1 1000BaseLHX port SC connector 40 km IM 1GZXSC Interface Module with 1 1000BaseZX po...

Page 14: ...45 connectors IM 4MSC Interface Module with 4 multi mode 100BaseFX ports SC connectors IM 4MST Interface Module with 4 multi mode 100BaseFX ports ST connectors IM 4SSC Interface Module with 4 single m...

Page 15: ...er Ports 100BaseFX ports SC ST connector Optical Fiber Distance Multi mode IM 4MSC IM 4MST IM 2MSC 2TX IM 2MST 2TX 0 to 5 km 1310 nm 50 125 m 800 MHz km 0 to 4 km 1310 nm 62 5 125 m 500 MHz km Single...

Page 16: ...00 4 4 EFT Level 3 EN61000 4 5 Surge Level 3 EN61000 4 6 CS Level 3 EN61000 4 8 EN61000 4 11 EN61000 4 12 Shock IEC60068 2 27 Free Fall IEC60068 2 32 Vibration IEC60068 2 6 WARRANTY 5 years Technical...

Reviews: