Panel Layout of EDS-505A/508A 
(Standard) 

 

EDS-505A

Front Panel View

EDS-508A

Front Panel View

7

6

8
9

11

10

12

13

14

15

15

2

14

15

15

MSTR/HEAD

CPLR/TAIL

MSTR/HEAD

CPLR/TAIL

 

V1, V2 INPUTS: 12-45 VDC

RS-232 CONSOLE

------

ON

OFF

MASTER

COUPLER
TURBO
RING

PWR1

4

3

2

1

PWR2

RELAY2

RELAY1

D

I

1

D

I

2

V2-

V2+

I

1

V1-

V1+

I

2

Top Panel View

1

2

3

4

1

Rear Panel View

2

17

16

16

5

2

 
1. Grounding 

screw 

2. 

Terminal block for power input 
PWR1/PWR2 and relay output

3. 

Heat dissipation orifices 

4. Console 

port 

5. DIP 

switches 

6. 

Power input PWR1 LED   

7. 

Power input PWR2 LED 

8. Fault 

LED 

9. 

MSTR/HEAD: LED indicator 

10.  CPLR/TAIL: LED indicator 
11. Turbo 

Chain 

logo 

12.  TP port’s 100 Mbps LED 
13. 

TP port’s 10 Mbps LED 

14. Model 

Name 

15. 10/100BaseT(X) 

ports 

16.  Screw hole for wall mounting kit 
17. DIN-Rail 

kit 

 
 
 
 

Summary of Contents for EDS-505A Series

Page 1: ...Hardware Installation Guide Eighth Edition July 2010 2010 Moxa Inc All rights reserved Reproduction without permission is prohibited Fl 4 No 135 Lane 235 Pao Chiao Rd Shing Tien City Taipei Taiwan R O C TEL 886 2 8919 1230 P N 1802005000017 ...

Page 2: ...contact your customer service representative for assistance y 1 Moxa EtherDevice Switch EDS 505A or EDS 508A y Hardware Installation Guide y CD ROM with User s Manual and Windows Utility y Warranty Statement y RJ45 to DB9 Console port cable y Protective caps for unused ports y Panel Mounting Kit optional must be ordered separately ...

Page 3: ...I2 V2 V2 I1 V1 V1 I2 Top Panel View 1 2 3 4 1 Rear Panel View 2 17 16 16 5 2 1 Grounding screw 2 Terminal block for power input PWR1 PWR2 and relay output 3 Heat dissipation orifices 4 Console port 5 DIP switches 6 Power input PWR1 LED 7 Power input PWR2 LED 8 Fault LED 9 MSTR HEAD LED indicator 10 CPLR TAIL LED indicator 11 Turbo Chain logo 12 TP port s 100 Mbps LED 13 TP port s 10 Mbps LED 14 Mo...

Page 4: ...earance of EDS 505A SS SC is identical to that of EDS 505A MM SC The appearance of EDS 508A SS SC is identical to that of EDS 508A MM SC 1 Grounding screw 2 Terminal block for power input PWR1 PWR2 and relay output 3 Heat dissipation orifices 4 Console port 5 DIP switches 6 Power input PWR1 LED 7 Power input PWR2 LED 8 Fault LED 9 MSTR HEAD LED indicator 10 CPLR TAIL LED indicator 11 Turbo Chain l...

Page 5: ... V1 I2 Top Panel View 1 2 3 4 1 Rear Panel View 2 19 18 18 5 2 1 Grounding screw 2 Terminal block for power input PWR1 PWR2 and relay output 3 Heat dissipation orifices 4 Console port 5 DIP switches 6 Power input PWR1 LED 7 Power input PWR2 LED 8 Fault LED 9 MSTR HEAD LED indicator 10 CPLR TAIL LED indicator 11 Turbo Chain logo 12 TP port s 100 Mbps LED 13 TP port s 10 Mbps LED 14 Model Name 15 10...

Page 6: ...5 55 7 5 27 20 48 30 MSTR HEAD CPLR TAIL DIN Rail Mounting The aluminum DIN Rail attachment plate should already be fixed to the back panel of the EDS 505A 508A when you take it out of the box STEP 1 Insert the top of the DIN Rail into the slot just below the stiff metal spring STEP 2 The DIN Rail attachment unit will snap into place as shown metal spring DIN Rail metal spring DIN Rail To remove E...

Page 7: ...ing the screw into one of the keyhole shaped apertures of the Wall Mounting Plates Do not screw the screws in completely leave about 2 mm to allow room for sliding the wall mount panel between the wall and the screws STEP 3 Once the screws are fixed in the wall insert the four screw heads through the large parts of the keyhole shaped apertures and then slide the EDS 505A 508A downwards as indicate...

Page 8: ...s with different signal characteristics should be routed separately y Use the type of signal transmitted through a wire to determine which wires should be kept separate The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together y Keep input wiring and output wiring separate y It is strongly advised that you label wiring to all devices in the system when...

Page 9: ...ative positive DC wires into the V V terminals STEP 2 To keep the DC wires from pulling loose use a small flat blade screwdriver to tighten the wire clamp screws on the front of the terminal block connector STEP 3 Insert the plastic terminal block connector prongs into the terminal block receptor which is located on the EDS s top panel ATTENTION Before connecting the EDS to the DC power inputs mak...

Page 10: ...nnector fiber ports 10 100BaseT X Ethernet Port Connection The 10 100BaseT X ports located on EDS s front panel are used to connect to Ethernet enabled devices Next we show pinouts for both MDI NIC type ports and MDI X HUB Switch type ports and also show cable wiring diagrams for straight through and cross over Ethernet cables MDI Port Pinouts MDI X Port Pinouts 8 pin RJ45 Pin Signal Pin Signal 1 ...

Page 11: ...A series are plug and play managed redundant Ethernet switches The proprietary Turbo Ring protocol was developed by Moxa to provide better network reliability and faster recovery time Moxa Turbo Ring s recovery time is less than 300 ms Turbo Ring or 20 ms Turbo Ring V2 compared to a 3 to 5 minute recovery time for commercial switches decreasing the possible loss caused by network failures in an in...

Page 12: ...tivates DIP switches 1 2 3 to configure Turbo Ring V2 settings OFF Enables the default Ring Coupling primary port OFF This EDS will not be the Ring Master OFF Do not use this EDS as a ring coupler OFF DIP switches 1 2 3 will be disabled NOTE You must enable the Turbo Ring function first before using the DIP switch to active the Master and Coupler functions NOTE If you do not enable any of the EDS ...

Page 13: ... is down MSTR HEAD GREEN Off When theEDS 505A 508A is not the Master of this Turbo Ring or is set as the Member of the Turbo Chain On When the EDS 505A 508A coupling function is enabled to form a back up path or when it s set as the Tail of the Turbo Chain Blinking When the Turbo Chain is down CPLR TAIL GREEN Off When the EDS 505A 508A disables the coupling function or is set as the Member of the ...

Page 14: ...port slider slider guide slider ridges slider slider guide slider ridges Specifications Technology Standards IEEE802 3 802 3u 802 3x 802 1D 802 1w 802 1Q 802 1p 802 1X 802 3ad Protocols IGMPv1 v2 GVRP SNMPv1 v2c v3 DHCP Server Client BootP TFTP SNTP SMTP RARP GMRP LACP RMON HTTP HTTPS Telnet Syslog DHCP Option 66 67 82 SSH SNMP Inform Modbus TCP LLDP IEEE 1588 PTP IPv6 MIB MIB II Ethernet Like MIB...

Page 15: ...e b using 62 5 125 μm 500 MHz km cable c using 9 125 μm 3 5 PS nm km cable d using 9 125 μm 19 PS nm km cable Power Input Voltage 12 to 45 VDC redundant inputs Input Current 24V Max 0 24A EDS 505A Max 0 26A EDS 508A Max 0 35A EDS 505A MM EDS 505A SS Max 0 36A EDS 508A MM EDS 508A SS Connection Two removable 6 pin terminal blocks Overload Current Protection Present Reverse Polarity Protection Prese...

Page 16: ...3 EN61000 4 8 EN61000 4 11 EN61000 4 12 Shock IEC60068 2 27 Freefall IEC60068 2 32 Vibration IEC60068 2 6 WARRANTY 5 years Technical Support Contact Information www moxa com support Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 10 6872 3958 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 0...

Reviews: