7
—
STEP 3
: Once the screws are fixed on the
wall, insert the four screw heads through
the large parts of the keyhole-shaped
apertures, and then slide the EDS-408A
downwards, as indicated. Tighten the four
screws for added stability.
II 3G
ATEX
Information
1.
Certificate number DEMKO 08 ATEX 0712961X
2.
Ambient range (-40
°
C
≤
Tamb
≤
75
°
C)
3.
Certification string (Ex nC nL IIC T4)
4.
Standards covered ( EN60079-0:2006, EN60079-15:2005)
5.
The conditions of safe usage:
y
These products must be mounted in an IP54 enclosure.
y
Install in an area of pollution degree 2 or less.
y
Use a conductor wire of size 0.2 mm² or greater.
y
PROVISIONS SHALL BE MADE, EXTERNAL TO THE
APPARATUS, TO PREVENT THE RATED VOLTAGE BEING
EXCEEDED BY THE TRANSIENTS DISTURBANCES OF MORE
THAN 40 %
Wiring Requirements
WARNING
Safety First!
Be sure to disconnect the power cord before installing and/or
wiring your Moxa EtherDevice Switch.
Calculate the maximum possible current in each power wire and
common wire. Observe all electrical codes dictating the
maximum current allowable for each wire size.
If the current goes above the maximum ratings, the wiring could
overheat, causing serious damage to your equipment.
Be sure to read and follow these important guidelines:
y
Use separate paths to route wiring for power and devices. If power wiring
and device wiring paths must cross, make sure the wires are perpendicular
at the intersection point.
NOTE: Do not run signal or communications wiring and power wiring
through the same wire conduit. To avoid interference, wires with different
signal characteristics should be routed separately.
y
Use the type of signal transmitted through a wire to determine which wires
should be kept separate. The rule of thumb is that wiring that shares similar
electrical characteristics can be bundled together.
y
Keep input wiring and output wiring separate.
y
It is strongly advised that you label wiring to all devices in the system,
when necessary.