background image

 

 

– 4 – 

– 5 – 

– 6 – 

 

www.moxa.com/support 

The Americas:   +1-714-528-6777 (toll-free: 1-888-669-2872) 

Europe:   +49-89-3 70 03 99-0 

Asia-Pacific:   +886-2-8919-1230 

China:   +86-21-5258-9955 (toll-free: 800-820-5036) 

 

 2011 Moxa Inc. All rights reserved. 

4.

 

If you see a warning that the software has not passed Windows 
Logo testing, select

 Continue Anyway

5.

 

After the driver software has been installed, the installation 

wizard will guide you through the port installation, starting 
with port 0. Be sure to install the software from the 

\

CP-114UL\Software\Windows 2K

 folder on the CD. 

6.

 

To verify successful installation, use 

Windows

 

Device 

Manager

 and check under 

Multi-port serial adapters and 

Ports (COM & LPT)

 for any special marks, such as a question 

mark or exclamation point. 

Linux (32-bit/64-bit)   

Ensure that you are logged into the machine with superuser (root) 

privileges. Insert the Moxa driver CD-ROM into the CD-ROM drive. 
If necessary, use the 

mkdir 

command to create a mount point for 

the CD-ROM. The following command creates a mount point in the 
directory /cdrom; you can mount the CD-ROM at any location in 

the machine’s local file system. 

mkdir /cdrom 

The commands in the steps below assume the CD-ROM is mounted 

at /cdrom. If you mount the CD-ROM at a different location, use 
that location when issuing commands. 
Mount the CD-ROM drive by entering the following command: 

# mount -t iso9660 -o ro /dev/cdrom /cdrom 

1.

 

Execute the following commands from the Linux prompt: 

 

#mount /dev/cdrom /mnt/cdrom 

#cd / 

#mkdir moxa 

#cd moxa 

#cp /mnt/cdrom/<driver directory>/mxser.tgz . 

#tar xvfz mxser.tgz 

#cd mxser 

#make clean; make install 

#cd /moxa/mxser/driver 

#./msmknod 

#modprobe mxser 

 

2.

 

Use the Moxa diagnostic utility to verify the driver status: 

 

#cd /moxa/mxser/utility/diag 

#./msdiag 

 

3.

 

Use the Moxa terminal utility to test the TTY ports: 

 

#cd /moxa/mxser/utility/term 

#./msterm #./msterm 

 
 

 

 

Pin Assignments and Cable Wiring 

The CP-112UL series has a female DB25 connector on the board. 
Cables with different connectors are available to help you connect 

your device to the board. 

Male DB9 (CBL-M25M9x2-50) 

 

Pin  RS-232  RS-422  RS-485 

4-wire 

RS-485 

2-wire 

DCD 

TxD-(A)  TxD-(A)  – 

RxD 

TxD+(B)  TxD+(B)  – 

TxD 

RxD+(B)  RxD+(B)  Data+(B) 

DTR 

RxD-(A)  RxD-(A)  Data-(A) 

GND 

GND 

GND 

GND 

DSR 

– 

– 

– 

RTS 

– 

– 

– 

CTS 

– 

– 

– 

 

The CP-114UL series has a female DB44 connector on the board. 

Cables with different connectors are available to help you connect 
your device to the board. 

Male DB9 (CBL-M44M9x4-50) 

 

Pin  RS-232  RS-422  RS-485 

4-wire 

RS-485 

2-wire 

DCD 

TxD-(A)  TxD-(A)  – 

RxD 

TxD+(B)  TxD+(B)  – 

TxD 

RxD+(B)  RxD+(B)  Data+(B) 

DTR 

RxD-(A)  RxD-(A)  Data-(A) 

GND 

GND 

GND 

GND 

DSR 

– 

– 

– 

RTS 

– 

– 

– 

CTS 

– 

– 

– 

 

 

 
 

 

 

Male DB25 (CBL-M44M25x4-50) 

 

Pin  RS-232  RS-422  RS-485 

4-wire 

RS-485 
2-wire 

TxD 

RxD+(B)  RxD+(B)  Data+(B) 

RxD 

TxD+(B)  TxD+(B)  – 

RTS 

– 

– 

– 

CTS 

– 

– 

– 

DSR 

– 

– 

– 

GND 

GND 

GND 

GND 

DCD 

TxD-(A)  TxD-(A)  – 

20  DTR 

RxD-(A)  RxD-(A)  Data-(A) 

 

 

 

 
 

 

Reviews: