CA Series User’s Manual
Software Installation
3-40
Port Configuration
After the driver is installed, a CA Series Properties window will appear. The system will map the
serial ports automatically. It will prompt you to take care of port configuration if another CA
Series module has been installed on the PC.
1.
Select a specific port under the
Port Configuration
tab and click
Port Setting.
2.
Under
Port Number
, select a COM number to assign to the serial port.
Select
Auto Enumerating COM Number
to map subsequent ports in numerical order. For
example, if COM 3 is assigned to Port 1, then COM 4 will be automatically assigned to Port 2.
3.
Select an
Rx FIFO Trigger.
The default value is 56 bytes (high level). Select
Set the change
to all ports
to use this setting for all serial ports on the module.