Moxa Technologies AirWorks AWK-1127 Quick Installation Manual Download Page 5

 

- 5 - 

Wall Mounting (optional) 

For some applications, it may be more convenient to mount the 
AWK-1127 to a wall, as illustrated below. 

STEP 1: 

Remove the aluminum 
DIN-Rail attachment plate 
from the AWK-1127, and 
then attach the wall mount 
plates with M3 screws, as 
shown in the adjacent 
diagrams. 

 

STEP 2: 

Mounting the AWK-1127 to a wall requires 4 screws. 
Use the AWK-1127 device, with wall mount plates 
attached, as a guide to mark the correct locations of 
the 4 screws. The heads of the screws should be less 
than 6.0 mm in diameter, and the shafts should be less 
than 3.5 mm in diameter, as shown in the figure at the 
right. 

 

Do not screw the screws in all the way—leave a space of about 2 mm to 
allow room for sliding the wall mount panel between the wall and the 
screws. 

NOTE 

Test the screw head and shank size by inserting the screw into 
one of the keyhole shaped apertures of the Wall Mounting Plates 
before it is screwed into the wall. 

 

 

STEP 3: 

Once the screws are fixed into the 
wall, insert the four screw heads 
through the large opening of the 
keyhole-shaped apertures, and 
then slide the AWK-1127 
downwards, as indicated to the 
right. Tighten the four screws for 
added stability. 

 

 
 

 

All manuals and user guides at all-guides.com

Summary of Contents for AirWorks AWK-1127

Page 1: ...ghts reserved Reproduction without permission is prohibited P N 1802011270012 AWK 1127 Quick Installation Guide Moxa AirWorks Second Edition June 2014 All manuals and user guides at all guides com a l...

Page 2: ...ting or distribution boxes The Din Rail mounting ability wide operating temperature range and IP30 housing with LED indicators make the AWK 1127 a convenient yet reliable solution for any industrial w...

Page 3: ...PWR2 3 RS 232 console port 4 AUX antenna port 5 System LEDs PWR FAULT and STATE LEDs 6 LEDs for signal strength 7 WLAN and LAN LEDs 8 10 100BaseT X RJ45 Port 9 MAIN antenna port 10 RS 232 422 485 Seri...

Page 4: ...Rail attachment plate to the AWK 1127 make sure the stiff metal spring is situated towards the top as shown in the figures below STEP 1 Insert the top of the DIN Rail into the slot just below the stif...

Page 5: ...m in diameter and the shafts should be less than 3 5 mm in diameter as shown in the figure at the right Do not screw the screws in all the way leave a space of about 2 mm to allow room for sliding the...

Page 6: ...ations wiring and power wiring in the same wire conduit To avoid interference wires with different signal characteristics should be routed separately You can use the type of signal transmitted through...

Page 7: ...terminals STEP 2 To keep the DC wires from pulling loose use a small flat blade screwdriver to tighten the wire clamp screws on the front of the terminal block connector STEP 3 Insert the plastic term...

Page 8: ...port You may then use a console terminal program to access the AWK 1127 for console configuration Console Pinouts for 10 pin or 8 pin RJ45 10 Pin Description 8 Pin 1 2 DSR 1 3 RTS 2 4 GND 3 5 TxD 4 6...

Page 9: ...N is transmitting data Off WLAN is not established or is not working properly LAN Green On 100 10 Mbps LAN port is active Blinking Data is being transmitted Off 100 10 Mbps LAN port is inactive TX RX...

Page 10: ...bps Typ 16 1 5 dBm 48 Mbps Typ 16 1 5 dBm 54 Mbps 802 11a Typ 18 1 5 dBm 6 to 24 Mbps Typ 16 1 5 dBm 36 Mbps Typ 15 1 5 dBm 48 Mbps Typ 14 1 5 dBm 54 Mbps RX Sensitivity 802 11b 97 dBm 1 Mbps 94 dBm 2...

Page 11: ...0 to 60 C 32 to 140 F Wide Temp Models 40 to 75 C 40 to 167 F Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity 5 to 95 non condensing Power Requirements Input Voltage 12 to 48 VDC...

Page 12: ...y cause undesired operation ATTENTION Do not locate the antenna near overhead power lines or other electric light or power circuits or where it can come into contact with such circuits When installing...

Page 13: ...69 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 Moxa...

Reviews: