AIG-500 Series HW UM
Hardware Introduction
2-5
Removal
STEP 1:
To unmount the AIG-500, pull down the latch
provided at the base of the mounting kit with a
screwdriver.
STEPS 2 & 3:
Slightly pull the AIG-500 forward and lift it up to
detach it from the DIN rail.
Wall Mounting (optional)
The optional wall-mounting kit is not included in the product package and should be purchased separately.
Follow these steps to mount the device on to a wall:
STEP 1:
Attach the wall-mounting brackets to the rear
side of the AIG-500 by using two screws per
bracket.
STEP 2:
Use four screws per side on the wall-mounting bracket to
attach the AIG-500 to a wall or cabinet.
IMPORTANT!
The diameter of the screw heads should be greater than 7 mm and less than 14 mm; the diameter of the
shafts should be less than 3 mm. The length of the screws should be greater than 6 mm.
NOTE
•
Test the screw head and shank size by inserting the screws into one of the keyhole shaped apertures of
the wall-mounting plates before attaching the plate to the wall.
•
Do not drive the screws in all the way—leave a space of about 2 mm to allow room for sliding the wall
mount panel between the wall and the screws.