This installation manual is written exclusively for competent professional personnel.
The installation, electrical connections and adjustments must be carried out conforming to good practice and 
according to the regulations in force.
Incorrect installation can cause a potential hazard. 
The packing materials (plastic, polystyrene, etc.) must not be allowed to pollute the environment, but must 
be  disposed  of  correctly,  and  must  not  be  left  within  the  reach  of  children  since  they  can  cause  possible 
hazards. 
Before starting installation, check the product is complete and undamaged. 
If the power cable is damaged, it must be replaced by the manufacturer or his technical support.
Do  not  install  the  product  in  an  explosive  environment  or  atmosphere:  the  presence  of  lammable  gas  or 
fumes is a serious health and safety hazard. 
Before installing the drive mechanism, put in place all the structural modiications relating to safety measures 
and to the protection or segregation of all the zones involving hazards of crushing, shearing, entrapment and 
of general hazard.
Check that all the existing structure has the necessary requirements of strength and stability. The manufacturer 
of the drive mechanism is not responsible for failing to conform to good practice in the construction of the 
windows to be opened, as well as any distortion which could occur during use.
Put up the notices laid down by current regulations to identify hazardous areas.
Ensure that the electrical supply is not a temporary one, but has the required electrical boxes, and in case of 
doubt or lack of (deinite) information, also install: 
-  suitable isolating transformers
- thermal magnetic cut-outs suitable to voltage requirements
- surge arrester. 
Before connecting the electrical supply, ensure that the electrical rating correspond to that of electrical di-
stribution supply. Fit onto the supply network an allpole switch with a contact gap of at least  3 mm.  Check 
that on the supply side of the electrical plant there is a suitable differential residual current circuit breaker 
and overload protection.
When  required  to  do  so,  connect  to  an  eficient  earthing/ground  system  itted  according  to  the  safety  re-
gulations  in  force  in  the  country  where  the  actuator  is  being  installed.    Before  carrying  out  any  operation 
(installation, maintenance or repair), isolate the electrical supply before working on the equipment. To en-
sure complete isolation from the supply current, installation is recommended of a double-pole switch of the 
approved type.

Summary of Contents for MSMART20H0B00

Page 1: ...Manuale di istruzioni per l uso INSTRUCTION MANUAL MODE D EMPLOI BEDIENUNGSANLEITUNG MANUAL DE INSTRUCCIONES...

Page 2: ...tly asked questions page 15 9 Guarantee page 16 10 CE Declaration Of Conformity page 17 1 GENERAL INFORMATION CONTENTS OF MANUAL 1 1 Introduction to this manual Please read carefully and follow the in...

Page 3: ...ability Themanufacturer of the drive mechanism is not responsible for failing to conform to good practice in the construction of the windows to be opened as well as any distortion which could occur du...

Page 4: ...vant standards issued by the European Community If the actuator is installed on a window at a height of less than 2 5 m from the loor and in buildings public and otherwise in which the use of destinat...

Page 5: ...ion W00 white version G00 grey version SMART Model MSMART20H0 MSMART20L0 Power supply VAC 230VCA 24VDC Frequency 50Hz 50Hz Operation S2 4min S2 4min Push strength 200N 200N Pull strength 250N 250N Str...

Page 6: ...ually in a cardboard box Each pack contains Electric actuator 230VAC 50Hz with electric supply cable support brackets ixing bracket for top hung window ixing bracket for bottom hung window and instruc...

Page 7: ...NOT POSSIBLE to it the actuator Check that the force required to open close it calculated according to the table under Point 4 2 is less than or equal to that shown in the TECHNICAL DATA table Try man...

Page 8: ...ype check that the limiting arms have been itted to prevent the window from accidentally falling down Bottom hung inward opening window With a pencil mark the mid point X of the window frame Top hung...

Page 9: ...Bottom hung inward opening window Top hung outward opening window Drill holes in the frame using the template supplied or the measurements shown on Page 7 Fix the brackets and the ixings using suitab...

Page 10: ...opening window Insert the side fulcrum pin into the support bracket Move the actuator towards the window frame in order to insert the opposite side fulcrum pin into the support bracket Rotate the actu...

Page 11: ...that the end of the chain can be inserted correctly inside the bottom hung window ixing Rotate the actuator in the opposite direction so that the end of the chain can be inserted correctly inside the...

Page 12: ...12 Bottom hung inward opening window Top hung outward opening window Removal of end cap Positioning the DIP switch Dip switch 1 Max 380 Min 180...

Page 13: ...acket by using the screws and slots Having reached the correct closing position press the control button and open the window in order to check that the actuator runs freely over the full travel set up...

Page 14: ...window follow the step sequence described on Page 11 in reverse order BEWARE OF THE DANGER of the window falling as the window is free to fall as it is no longer held up by the chain Once the maintena...

Page 15: ...corresponds to voltage supply detected The actuator is not travel ling the distance required The window opening is not as required Check that according to the table on Page 13 the DIP switch is set f...

Page 16: ...t of the product shall be reported by the Buyer within 8 eight days from its discovery or from the date of delivery of the goods under penalty of invalidation of the warranty Such claim shall be notii...

Page 17: ...ormity with the basic requirements of the following European Directives Directive 2006 95 EC Low Voltage Directive and following amendments Directive 2004 108 EC EMC Directive and following amendments...

Reviews: