1. Specifications

Measuring range

30 - 300 Nm

22 - 222 lbf.ft

Measuring units (computed)

0

.

1 Nm - 0

.

1 lbf.ft. (1 Nm = 0

.

74 lbf.ft)

Lowest  torque indicated

0

.

3 Nm

Drive

1/2“ square joint

Accuracy

1% ± 1 digit of the current reading

Measurement display

LCD, 4 digits / special characters, digital

Measurement transducer

Bending beam with full bridge circuit 4 x 1200 Ohm, controlled by microcontroller

Power supply

3 AA size batteries (mignon), replaceable by customer. Suitable are:

- 3x 1

.

5 V alkaline approx. 2500 mAh (supplied)

- 3x 1

.

5 V ZnC approx. 1500 mAh

- 3x 1

.

2 V NiMH rechargable approx. 1300 mAh

- 3x 1

.

2 V NiCd rechargable approx. 900 mAh

(the mAh values vary with brand and type)

Battery life time

Using 3x 1

.

5 V alkaline batteries:

display only: min. 1400 hsleep mode: max. 8500 h

Temperature

+5°C to +35°C +40°F to +95°F

Calibration

Automatic -0- calibration at the touch of a key

Direction of rotation

Clockwise and anticlockwise

Dimensions

L: 573 mm  

∅: 

max. 40 mm

Weight

3.1 lbs.

Reading memory

2000 readings

Memory bank

1 bank, Data sequentiell stored

Data memory

8K Byte Eeprom

Interface

RS232 serial

Transmission rate

1200 Baud

8 data bit

1 stop bit

no Parity

no protocoll

Jack

3.5mm jack 3 pole

RS232 - interface

Function

special characters

Rated value
Percent minus
Percent plus
Nm
Lbf.ft.
Sleep timer
Memory
Print

Technical Data  

Summary of Contents for TorcoTronic

Page 1: ...TorcoTronic Operating Instructions Rev 1 0 Corporate Headquarters 1080 North 11th Street San Jose CA 95112 Phone 408 292 2214 Fax 408 292 2733 www etorque com Mountz Inc ISO 9001 2000 company ISO 9001 ...

Page 2: ...echargable approx 1300 mAh 3x 1 2 V NiCd rechargable approx 900 mAh the mAh values vary with brand and type Battery life time Using 3x 1 5 V alkaline batteries display only min 1400 hsleep mode max 8500 h Temperature 5 C to 35 C 40 F to 95 F Calibration Automatic 0 calibration at the touch of a key Direction of rotation Clockwise and anticlockwise Dimensions L 573 mm max 40 mm Weight 3 1 lbs Readi...

Page 3: ...1 Measuring hold 1x MODE key 1 Increase current digit MODE key 1 Go to the next digit SELECT key 2 2 Commissioning Activate the torque wrench from sleep mode press any key The decimal point flashes in sleep mode Decimal point does not flash torque wrench not operational replace exhausted batteries Torque wrench is initializing Torque wrench operational Readings may be taken immediately Measuring t...

Page 4: ... 1 Toggle setting using SELECT key 2 Setting the tolerance limits Select function set rated value press 1x MODE key 1 Display operational Torque wrench operational Display Rated value Enter lower tolerance limit in percentage of the rated value 4 Set value using SELECT key 2 Setting 4 press 3x SELECT key 2 The tolerance limits are set Continue with Nm lbf ft press MODE key 1 Measuring hold MODE ke...

Page 5: ...ercent plus Display Nm lbf ft press 1x MODE key 1 press 1x MODE key 1 press 1x MODE key 1 press 1x MODE key 1 press 1x MODE key 1 press 1x MODE key 1 press 1x SELECT key 2 Setting the sleep timer The sleep timer is set Continue with Measuring press MODE key 1 Set value using SELECT key 2 Setting 6 minutes Set sleep timer 6 minutes Select function set sleep timer Display Sleep timer Select function...

Page 6: ...wn press 1x SELECT key 2 press 1x MODE key 1 release SELECT key 2 Select function Print press 1x SELECT key 2 Select function Print Select function set rated value Display operational Function Print selected Continue with Measuring press MODE key 1 Select function set permissible percent minus Select function Nm lbf ft Select function set permissible percent plus Display Memory Select function Mem...

Page 7: ...nce limit Current torque reading below the rated value and below the lower tolerance limit No signal Signal green LED beeper Signal green LED red LED beeper Signal red LED press 1x SELECT key 2 The displayed reading is cleared Clear the displayed reading Display operational Torque wrench operational Torque wrench operational Calibration Recalibrate the torque wrench Reading is re set to zero Self ...

Page 8: ... with the CE standard Display batteries changed Torque wrench operational Battery level Low battery Display for approx 6 sec before torque wrench enters sleep mode Sleep mode decimal point flashes Batteries should be replaced Sleep mode decimal point does not flash LbAt and Sleep mode alternate Batteries must be replaced Batteries exhausted Note Should the LbAt display appear during measuring with...

Reviews: