GENERAL SAFETY RULES 

 
WARNING! Read and understand all instructions. Failure to follow all instructions listed below, may result in electric shock, 
fire and/or serious personal injury 
 

SAVE THESE INSTRUCTIONS 

 

Work Area 

Keep your work area clean and well lit. Cluttered benches and dark areas invite accidents. 
Do not operate power tools in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust. Power 
tools create sparks which may ignite the dust or fumes. 
Keep bystanders, children, and visitors away while operating a power tool. 
Distractions can cause you to lose control. 
 
 

Electrical Safety 

Grounded  tools  must  be  plugged  into  an  outlet  properly  installed  and  grounded  in  accordance  with  all  codes  and 
ordinances. Never remove the grounding prong or modify the plug in any way. Do not use any plugs. Check with a qualified 
electrician if you are in doubt as to whether the outlet is properly grounded. If the tools should electrically malfunction or 
break down, grounding provides a low resistance path to carry electricity away from the user. 
Avoid  body  contact  with  grounded  surface  ad  pipes,  radiators,  ranges  and  refrigerators.  There  is  an  increased  risk  of 
electric shock if your body is grounded. 
Don't expose power tools to rain or wet conditions. Water entering a power tool will increase the risk of electric shock 
Do not abuse the cord. Never use the cord to carry the tools or pull the plug from an outlet. Keep cord away from heat, 
oil, sharp edges or moving parts. Replace damaged cords immediately. Damaged cords increase the risk of electric shock. 
When operating a power tool outside, use an outdoor extension cord marked W-A or W. These cords are rated for outdoor 
use and reduce the risk of electric shock. 
 
 

Personal Safety 

Stay alert, watch what you are doing and use common sense when operating a power tool. Do not use tool while tired or 
under the influence of drugs, alcohol, or medication. A moment of inflation while operating power tools may result in 
serious personal injury. 
Dress properly. Do not wear loose clothing or jewelry. Contain long hair. Keep your hair, clothing, and gloves away from 
moving parts. Loose clothes, jewelry, or long hair can be caught in moving parts. 
Avoid accidental starting. Be sure switch is off before plugging in. Carrying tools with your finger on the switch or plugging 
in tools may result in personal injury. 
Remove adjusting keys or switches before turning the tool on. A wrench or a key that is left attached to a rotating part of 
the tool may result in personal injury. 
Do not overreach. Keep proper footing and balance at all times. Proper footing and balance enables better control of the 
tool in unexpected situations. 
Use safety equipment. Always wear eye protection. Dust mask, non-skid safety shoes, hard hat, or hearing protection 
must be used for appropriate conditions. 
Tool use and Care 
Use clamps or other practical way to secure and support the workplace to a stable platform. Holding the work by hand or 
against your body is unstable and may lead to loss of control. 
Do not force tool. Use the correct tool for your application. The correct tool will do the job better and safer at the rate for 
which it is designed. 
Do not use tool if switch does not turn it on or off. Any tool that cannot be controlled with the switch is dangerous and 
must be repaired. 

Summary of Contents for E-DRIV MD-Series

Page 1: ...www mountztorque com 1080 N 11th St San Jose CA 95112 408 292 2214 1 Revision 1 1 July 05 2017 E DRIV MD Series DC Torque Control System Calibration Procedure...

Page 2: ...amaged cords increase the risk of electric shock When operating a power tool outside use an outdoor extension cord marked W A or W These cords are rated for outdoor use and reduce the risk of electric...

Page 3: ...orly maintained tools Use only accessories that are recommended by the manufacturer for your model Accessories that may be suitable for one tool may become hazardous when used on another tool SERVICE...

Page 4: ...justed when customer validates tool with their torque master equipment and there is a difference between tool and master readings This calibration is also performed when Mountz services the tool as pa...

Page 5: ...Devices will provide different results Make sure you always use the same ISO17025 Torque Tester Master Device with the same accessories and testing conditions RDA Tool Speed Tester Filter Setting Torq...

Page 6: ...h St San Jose CA 95112 408 292 2214 6 Tool Compensation Torque compensation using controller panel Tool Compensation Torque compensation using ParaMon software Total adjustable range is 20 80 to 120 f...

Page 7: ...ur tool s craftsmanship and our ability to provide solutions to both common and uncommon torque applications We perform calibrations in accordance with ANSI NCSL Z540 Mountz is dedicated solely to the...