Power

Securely place the power cord into the back of the STC30 Plus. Flip the switch on the back to turn on the unit: Light turns Green.

Connecting Electric Screwdriver

Before connecting the electric screwdriver, make sure the little switch in the lower 
bottom right of the STC 30 Plus (v4.1) is positioned in the proper setting (EF or K).
See diagram. Only operate tool in proper “Mode” setting. 

EF Mode

K Mode

Low = Output is 20VDC

Low = Output is 30VDC

High = Output is 30VDC

High = Output is 38VDC

Electric Drivers to use in EF Mode:

Electric Drivers to use in K Mode:

A4500- 5000

K150-450

SS300-7000
CL2000-7000
EF080-120
BF080-120

Note: 

There are two models of the STC30 Plus v4.1
Item #145683 

Operates: 

A-Series, CL-Series, EF-Series,  

K-Series, BF-Series

Item #145684 

Operates: 

SS-Series 

1. Attach cord of the electric screwdriver to the transformer. Make sure notch in plug lines up with the notch in the socket. 

Tighten knurled ground ring.

2. Select HIGH & LOW speed button. Select the appropriate speed for your application.
3. Turn driver on and check for proper rotation. FOR-clockwise, REV-counterclockwise.
4. To apply torque, squeeze the lever (For Push-to-Start models place light downward pressure on the nose of the driver). The driver will 

automatically stop when the preset torque has been reached. 

Soft Start Mode

Press the "sT" button in the lower bottom right. The power light will blink once and turn 

Yellow

, which indicates that you are in Soft Start

mode. There are 4 different time settings for the Soft Start mode which are (0.2, 0.3, 0.5, & 0.6 seconds). When you select this mode it
starts at 0.2 seconds. 

The unit has EEP ROM, which allows the settings for the soft start and double hit to be kept once an operator turns off unit and then back
on. Example: If the transformer is set at the 0.6 seconds setting for the soft start mode and the unit is turned off, it will keep that setting
when unit is turned on

Push “sT” Button

Function

LED Light

0

Standard

Green

1st

Soft Start 0.2 Seconds

Yellow Light Blinks Once

2nd

Soft Start 0.3 Seconds

Yellow Light Blinks Twice

3rd

Soft Start 0.5 Seconds

Yellow Light Blinks Three times

4th

Soft Start 0.6 Seconds

Yellow Light Blinks Four times

5th

Double Hit Mode

Red

STC30 Plus (v4.1) Transformer

(Rev 1.0 8/8/08)

EF

K

sT

Soft Start &
Double Hit
function

Make sure the switch is correct position

before operating. Either EF or K mode.

Corporate Headquarters: 

1080 North 11th Street, San Jose, CA 95112    Phone: (408) 292-2214   Fax: (408) 292-2733

www.etorque.com

Page 2

Quick Reminder

Green

Light = Operating in Standard mode

Yellow

Light = Operating in Soft Start mode

Red

Light = Double Hit mode

Summary of Contents for 145683

Page 1: ...Plus v4 1 Operation Instructions Corporate Headquarters 1080 North 11th Street San Jose CA 95112 Phone 408 292 2214 Fax 408 292 2733 www etorque com RoHS Power Supply for Electric Screwdrivers Rev 1 0...

Page 2: ...river The driver will automatically stop when the preset torque has been reached Soft Start Mode Press the sT button in the lower bottom right The power light will blink once and turn Yellow which ind...

Page 3: ...l shut down automatically when the current exceeds 12 13A The controller should be reset by turning off the power switch for one minute and turned back on If the current is not over the limit power wi...

Page 4: ...8 White Brown Not Used RJ 11 Modular Jack 2M 1 5M Corporate Headquarters 1080 North 11th Street San Jose CA 95112 Phone 408 292 2214 Fax 408 292 2733 www etorque com Page 4 1 5 4 3 2 1 Motor 2 Limit...

Page 5: ...Blue stripe Green stripe PLC connections Electric Screwdriver STC30 Plus Scout Screw Counter PLC PLC Signal Out Cycle End NG OK Buzzer Signal In Cycle Start Driver Lock Signal In Driver Lock Signal Ou...

Page 6: ...ce Converter STC 30 Plus Accessory The PLC interface converter provides three types of signals by converting the open collector signal from STC 30 Plus Model U 3 Item 145619 Size WxDxH 3 x 2 3 8 x 3 4...

Page 7: ...nction 2 1 Buzzer does not stop sound when the power is on There are two possible problem One is the micro processor IC The other is the SB21 sub board Push the sT button soft start button If the colo...

Page 8: ...ing is not same 20 30 38V as the set position EF with Low K with Low K with High check and replace the voltage selector switch slide switch The High Low switch should be also checked 6 Screwdriver kee...

Page 9: ...e of failure please test the component with multi tester as below Page 9 Step 01 Step 02 With the failure of Q33 and Q31 the following components are commonly damaged too Check the following process T...

Page 10: ...ers 1080 North 11th Street San Jose CA 95112 Phone 408 292 2214 Fax 408 292 2733 www etorque com Damaged Fuse make Open by short circuit test Damaged Thermistor make Open by short circuit test Rectifi...

Reviews: