ERROR LOCALISATION
25
Problem
Solution
1
Sauna does not
work, the con-
trol panel does not
display anything
1
Check correct connection
to power
2
Check the switch on the control box (top
plate)
3
Check connection of the current fuse on the
control box (if disconnected press it down)
2
Heaters do not
heat
1
Connect the sauna, switch it on and check
whether the temperature on the sauna display
is the same as the ambient temperature
2
If the temperature on the display is the same
check whether the temperature setpoint is
higher than the ambient temperature
3
If this is the case have cable connections and
function of the control box checked.
3
Bench heater
does not work
1
Check function of the other heaters. If they
work check cable connections under the bench
4
The display on
the
control
panel does not show
anything
1
Check the control panel for the beep sound af-
ter pressing the POWER button
2
Check the control unit for the clicking sound
after pressing the POWER button
3
Check cable plugs for correct connection and
securing
4
If all 3 points above are OK the control panel
needs replacing (if the sauna is equipped with
two control panels and only one of them does not
work replace the non-functioning control panel)
5
if the sounds described under 1 and 2 above can-
not be heard the control unit needs replacing
5
The
radiator
works, the tem-
perature inside the
sauna increases but
the temperature dis-
play does not change
1
Check the temperature sensor for correct posi-
tion (in the top plate). If the position is correct
replace the sensor.