background image

Instructions for Pro Hunter II Feeder Kit

THANK YOU for your purchase of a Moultrie Pro Hunter II Feeder Kit. Please read this sheet before  

operating the unit. If you should have any questions about this product or any other Moultrie product, 

please contact us at 

www.moultriefeeders.com/support

. Allow us to better serve you by  

activating your 1-year warranty online at 

http://www.moultriefeeders.com/warranty

If mounting the Moultrie Quick Lock Feeder Kit to:

 • a Moultrie 30 or 55-gallon barrel* or Moultrie 6.5-gallon bucket, refer to 

Section C

.

 • a Moultrie 30-Gallon Quick-Lock Hopper, refer to 

Section D

 • any other containers, please visit our website at 

www.moultriefeeders.com

STOP

READ THIS FIRST

BEFORE

PROCEEDING

CONFIGURING AND TESTING FEEDER

A

FCC  COMPLIANCE

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

For devices approved under Part 15, the user’s manual or instruction manual for an intentional or unintentional radiator shall caution the user about changes or modifications to the device (Section 15.21).

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment  
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.  
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 
 

– Reorient or relocate the receiving antenna.

 

– Increase the separation between the equipment and receiver. 

 

– Connect the equipment into an outlet on a circuit different  from  that to which the receiver is connected. 

 

– Consult the dealer or an experienced radio/TV technician for help.

SET CURRENT TIME:

 

Press the PROGRAM button and SET CURRENT TIME will appear. Press UP or DOWN to set the 

hour, then press RIGHT to go to the minutes. Press UP or DOWN to set the minutes. Press the BACK button to return 
to the Main Menu , or press PROGRAM to proceed through the settings.

NOTE: The timer is capable up to 10 feed times, each 1-60 seconds each, and each can operate on any day of 
the week where each day can be toggled ON/OFF.

SET CURRENT DAY: 

Press the PROGRAM button until the Set Current Day screen appears. Press LEFT or RIGHT to 

select the current day. Press BACK to return to the Main Menu, or press PROGRAM to proceed through the settings.

SET EST. FEED REMAINING: 

Press the PROGRAM button until the Est. Feed Remaining screen appears. Press UP or 

DOWN to select the amount of feed you have in the feeder. Press BACK to return to the Main Menu, or press 
PROGRAM to proceed through the settings. 

SET FEED TIME: 

Press the PROGRAM button until the desired Feed Timer appears at the top of the screen. Press the 

DOWN button until the feed time is flashing. Press PROGRAM to enter edit mode. Press UP or DOWN to set the hour. 
Press the RIGHT button to go over to the minutes. Press UP or DOWN to set the minutes. Press PROGRAM or BACK to 
return to the Feed Timer. The factory settings include two feeder times 7am and 6pm, each for 6 seconds.

SET DAYS OF THE WEEK:

 After setting the feed time, press UP so the days of the week start flashing. Press PROGRAM 

to enter edit mode. By default all days should be enabled. Press LEFT or RIGHT to highlight the desired day. Press 
DOWN to disable the selected day. Press UP to re-enable the selected day. Once all desired days are selected, press 
PROGRAM or BACK to return to the Feed Timer.

SET RUN DURATION:

 Press DOWN and LEFT until the RUN DURATION seconds are flashing. Press PROGRAM to enter 

edit mode. Press UP or DOWN to set desired feed duration. Press PROGRAM or BACK to return to the Feed Timer.  

SET MOTOR SPEED: 

Press UP or DOWN until the motor speed setting is flashing at the bottom of the screen. Press 

PROGRAM to enter edit mode. Press RIGHT or LEFT to select the desired motor setting. Press PROGRAM or BACK to 
return to the Feed Timer.
 

When the Feed Timer is blinking at the top of the screen, press PROGRAM or RIGHT to advance to the next feed 
timer.  Repeat for all required feed times. 

TEST FEEDER:

 Press the BACK button to reach the Main Menu. Press the TEST button to enter the Test Mode. The 

Test duration will appear (this will be the same as the duration as Feed Timer 1). Press UP or DOWN to set the Test 
Duration. Press PROGRAM. Press RIGHT or LEFT to select desired motor speed. Press PROGRAM to perform test. 