Uf251_01d_oi_e.doc / Aug-16
Page 15 / 25
7.
PC Setup with Use of the Operator
Software OS6.x
You can apply the full set of functions of the UF251 converter when using a PC and our operator
software OS6.x for setup of the unit. The software is available for free download under
Connect your PC to the converter using a serial RS232 cable like shown in section
this manual. Make sure the cable only uses pins 2, 3 and 5. Pins 2 and 3 must be
crossed.
Run the OS6.x software and you will see the screen shown below.
In case your text and color fields should remain empty and the headline says „OFFLINE“,
you must verify the setting of DIL switch positions 1 and 6 and check your serial
settings. Select „Comms“ from the menu bar to check for serial settings.
Ex factory, all motrona units use the following serial default settings:
RS232, Unit No. 11, Baud Rate 9600, 1 start bit, 7 data bit, parity even, 1 stop bit
If the serial settings of your unit should be unknown, you can run the „Scan“ function
from the „Tools“ menu to find out.