Pu204_02c_oi_e.doc / Apr-16
Page 10 / 10
7.
Technical Specifications
Power supply:
Input voltage:
Protection:
Ripple:
Consumption:
Connections:
10 … 30 VDC
reverse polarity protection
and fuse (0, 315 A medium time lag)
≤
10 %
approx. 85 mA (unloaded)
selectively by 1.5 mm² / AWG 16 screw terminal
or 9-pin female SUB-D connector
Encoder supply:
Output voltage:
Connections:
5 VDC / max. 100 mA (switchable)
selectively by 1.5 mm² / AWG 16 screw terminal
or 9-pin male SUB-D connector
Inkremental input:
Levels:
Channels:
Frequency:
Connections:
5 V-TTL / RS422
A, /A, B, /B, Z, /Z
max. 200 kHz
male SUB-D connector, 9-pin
Inkremental output:
Levels:
Output logic:
Channels:
Output current:
Signal delay time:
Connections:
5 V-TTL / RS-422
push-pull
A, B, Z
max. 30 mA per channel
approx. 800 ns
female SUB-D connector, 9-pin
Housing:
Material:
Mounting:
Dimensions (w x h x d):
Protection class:
Weight:
plastic
35 mm top hat rail (according to EN 60715)
78 x 90 x 70 mm / 3.071 x 3.543 x 2.756 inch
IP20
approx. 100 g
Ambient temperature:
Operation:
Storage:
0 °C … +45 °C / +32 … +113 °F (not condensing)
-25 °C … +70 °C / -13 … +158 °F (not condensing)
Failure rate:
MTBF in years:
83.1 a (long-term usage at 60 °C / 140 °F )
Conformity & standards: EMC 2004/108/EC:
Guideline 2011/65/EU:
EN 61000-6-2, EN 61000-6-3, EN 61000-6-4
RoHs-conform