background image

Operating Manual 

 

 

motrona GmbH, Zeppelinstraße 16, DE - 78244 Gottmadingen, Tel. +49 (0) 7731 9332-0, Fax +49 (0) 7731 9332-30, [email protected], www.motrona.com

 

 

 
 

 

 
 
 
 

GV204 

Impulse Splitter for Incremental Encoders 

 
 

         Product features: 

 

 

Programmable encoder input A, /A, B, /B, Z, /Z, for use with RS422 or  
TTL differential signals or with HTL signals (differential or single-ended) 

 

Two encoder outputs (A, /A, B, /B, Z, /Z each) with individually programmable  
output levels (TTL 5 V or HTL 10 to 30 V) 

 

Max. frequency 750 kHz (TTL) or 300 kHz (HTL) 

 

Power supply either 5 VDC or 10 to 30 VDC 

 

Aux. voltage 5 V for encoder supply  
(with 10 to 30 VDC power supply) 

 

Summary of Contents for GV204

Page 1: ...atures Programmable encoder input A A B B Z Z for use with RS422 or TTL differential signals or with HTL signals differential or single ended Two encoder outputs A A B B Z Z each with individually programmable output levels TTL 5 V or HTL 10 to 30 V Max frequency 750 kHz TTL or 300 kHz HTL Power supply either 5 VDC or 10 to 30 VDC Aux voltage output 5 V for encoder supply with 10 to 30 VDC power s...

Page 2: ... GmbH Any reproduction modification usage or publication in other electronic and printed media as well as in the internet requires prior written authorization by motrona GmbH Table of Contents 1 Safety Instructions and Responsibility 3 1 1 General Safety Instructions 3 1 2 Use according to the intended purpose 3 1 3 Installation 4 1 4 Cleaning Maintenance and Service Notes 5 2 Compatibility Hint 6...

Page 3: ...serve the right to modify the hardware software or operation manual at any time and without prior notice Therefore there might be minor differences between the unit and the descriptions in operation manual The raiser respectively positioner is exclusively responsible for the safety of the system and equipment where the unit will be integrated During installation or maintenance all general and also...

Page 4: ... connected exclusively by switches respectively circuit breakers with the low voltage network The switch or circuit breaker must be placed as near as possible to the device and further indicated as separator Incoming as well as outgoing wires and wires for extra low voltages ELV must be separated from dangerous electrical cables SELV circuits by using a double resp increased isolation All selected...

Page 5: ...ic shielding instructions of the manufacturer are valid Please find all respective hints and rules on www motrona com download html General EMC Rules for Wiring Screening and Earthing 1 4 Cleaning Maintenance and Service Notes To clean the front of the unit please use only a slightly damp not wet soft cloth For the rear no cleaning is necessary For an unscheduled individual cleaning of the rear th...

Page 6: ...cation The GV 204 splitter has been designed for proper and trouble free splitting of encoder signals to two target units Where signals have to be distributed to more targets it is easy to cascade several units or to use a multi splitter like GV470 If applicable the unit can at the same time operate as a level converter between TTL RS422 levels and HTL 10 30 V levels It is possible to use only inp...

Page 7: ...ll essential circuit details of a GV204 unit GND Vout Shield VB Vext GND A A B B Z Z GND GND A A B B Z Z 5 4V VB TTL HTL TTL HTL VB 5 4V Input Sub D 9 male Output 2 Sub D 9 female A A B B Z Z 3 5 4 2 1 9 7 6 3 2 1 9 7 6 3 2 1 9 7 6 5 5 Output 1 Sub D 9 female IN HTL TTL OUT1 Vext OUT2 Vext ...

Page 8: ...er simulation of a drive which is also intended to supply the splitter Units supplied with 5 V only are unable to generate output levels higher than 5 V In case of a 5 VDC supply via Vext and desired TTL output levels however the respective DIL switch setting must be HTL Vext The screw terminal marked Shield connects the metallic housings of the SUB D connectors only Depending on individual needs ...

Page 9: ...e Signal Levels Required Input Signals Aux Output Pin 4 Encoder Supply ON 1 2 3 4 5 6 RS422 Diff 1V TTL 5 V HTL 10 30 V Differential signals A A B B Z Z inverted signals are must 5 4 V respectively Vext ON 1 2 3 4 5 6 HTL 10 30 V Single ended signals A B Z no inverted signals required VB 1 4 V respectively Vext Other switch positions than shown above are reserved for special applications and must ...

Page 10: ... TTL OUT1 HTL Vext OUT2 TTL OUT2 HTL Vext 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON With output format TTL and powering via VB the output level is always 5 V With output format HTL Vext the output level approx corresponds to the supply voltage VB When terminal Vext receives a voltage higher than the power supply VB resp the unit is powered via the Vext input the output level will correspond to V...

Page 11: ...Gv204_01c_oi_e doc Apr 16 Page 11 12 8 Dimensions 23456 85 3 346 90 3 543 38 1 496 50 1 969 1234 1 ...

Page 12: ...A A B B Z Z max 750 kHz RS422 TTL differential max 350 kHz HTL SUB D connector male 9 pin Frequency outputs Number of outputs Signal levels Channels Output current Output circuit Signal propagation delay Connections 2 either TTL 5 V or HTL power supply voltage minus approx 1 4 V A A B B Z Z max 30 mA per output push pull approx 700 ns SUB D connectors female 9 pin Housing Material Mounting Dimensi...