Safety Instructions 

 
 

 

This manual is an essential part of the unit and contains important hints about 
function, correct handling and commissioning. Non-observance can result in 
damage to the unit or the machine or even in injury to persons using the  
equipment! 

 

 

The unit must only be installed, connected and activated by a qualified electrician 

 

 

It is a must to observe all general and also all country-specific and application-
specific safety standards 

 

 

When this unit is used with applications where failure or maloperation could cause 

damage to a machine or hazard to the operating staff, it is indispensable to meet 
effective precautions in order to avoid such consequences 

 

 

Regarding installation, wiring, environmental conditions, screening of cables and 
earthing, you must follow the general standards of industrial automation industry 

 

 

- Errors and omissions excepted – 

 
 

 
 
 

 
 
 

 
 
 

Version: 

Description:  

GV15502B/ TJ/ Sep 03/ P1...7,2 

GV155-1 renamed to GV156 Block diagram revised 

 

 

 

 

 

Summary of Contents for GV155

Page 1: ...switch for encoders RS422 A A B B Z Z or HTL 15 30V 2 x 2 Cross matrix switch for analogue signals 10V Cascadable inputs and outputs Bounce free electronic switching of all channels PLC compatible con...

Page 2: ...ve all general and also all country specific and application specific safety standards When this unit is used with applications where failure or maloperation could cause damage to a machine or hazard...

Page 3: ...g Diagrams 6 3 1 Encoder inputs GV155 and GV156 with TTL level 6 3 2 Encoder inputs GV156 with HTL level Option HTLIN1 6 3 3 Encoder outputs GV155 and GV156 6 3 4 Analogue inputs and outputs 6 3 5 Con...

Page 4: ...IN2 A A A A 1 300R 300R GV155 All encoder inputs and outputs are designed for TTL level RS422 line driver signals GV156 Encoder inputs are available with TTL RS422 format standard or with HTL 15 30V...

Page 5: ...are also unacceptable screening and wiring problems when using relays Use of GV155 or GV156 avoids any of these problems and allows proper and reliable switching of digital and analogue signals There...

Page 6: ...out N Both connectors Sub D 9 male on unit site GND 1 2 3 4 5 9 8 6 7 Encoder input 2 B A 24Vout N 3 3 Encoder outputs GV155 and GV156 GND 1 2 4 5 9 8 6 7 B A A B N N GND 1 2 3 4 5 9 8 6 7 B A A B N N...

Page 7: ...5 but not with GV156 Low High 0 5 V 15 30 V Sub D 25 male on unit site 4 Output Level Selection GV156 only To select the desired output level please remove the right hand side plate and set the DIL sw...

Page 8: ...Option HTLIN1 Encoder Outputs RS422 5V 20 mA GV155 5V 24V 50 mA GV156 Analogue inputs 10V RIN 100 k Analogue Outputs 10V ROUT 300 Analogue accuracy 0 05 Analogue Offset drift 0 3 mV Control Inputs Low...

Page 9: ...GV15502B_e DOC Mrz 08 Page 9 9 6 Dimensions 122 5 129 111 70 7 11 70 5 171 188 197 55 5 70 5 45 70 Vorderansicht Seitenansicht R ckansicht Draufsicht Rear view Front view Side view Top view...