DZ27001a_e.doc / Jan-13
Page 25 / 36
Switching -Menu
(Switching characteristics of the relays/outputs)
Code Setting Range Default
Start up Mode
Start-up-delay after power-up and after standstill
„G8“
0..10
0
0
No start-up-delay
1
Start-up-delay 1 second
2
Start-up-delay 2 seconds
3
Start-up-delay 4 seconds
4
Start-up-delay 8 seconds
5
Start-up-delay 16 seconds
6
Start-up-delay 32 seconds
7
Start-up-delay 64 seconds
8
Start-up-delay 128 seconds
9
Automatic delay until to first overstepping of the set value
10 Start-up-delay by remote signal
Start up Relay
Assignment of a start-up-delay function to the relays/outputs
„G9“
0..7
0
0
No start-up-delay for any of the relays
1
Relay 1/transistor output 1 provides start-up-delay
2
Relay 2/transistor output 2 provides start-up-delay
3
Relays 1&2/transistor output 1&2 provide start-up-delay
4
Relay 3/transistor output 3 provides start-up-delay
5
Relays 1&3/transistor output 1&3 provide start-up-delay
6
Relays 2&3/transistor output 2&3 provide start-up-delay
7
All relays provide start-up-delay
Lock Relay
Assignment of a catch function to the relays *)
„H0“
0..15
0
0
No catch function for any of the relays
1
Relay 1/output 1 with catch (release by key/control input)
2
Relay 2/output 2 with catch (release by key/ control input)
3
Relays 1&2/output 1&2 with catch (release by key/control
input)
4
Relay 3/output 3 with catch (release by key/control input)
5
Relays 1&3/output 1&3 with catch (release by key/control
input)
6
Relays 2&3/output 2&3 with catch (release by key/control
input)
7
all Relays/outputs with catch (release by key/control input)
8-15 similar to 0 - 7, but catch to release by key/by control input
and automatically upon standstill
Standstill Time
Time setting for standstill definition
A time of xx.xx seconds after detection "zero input frequency" the
unit signals "standstill" and re-activates the start-up-delays
„H1“
0..99.99
0
*) According to parameter settings, the catch situation can be released by either pressing one of the front
keys or by a remote control signal or automatically upon detection of standstill (see "Command menu"