background image

20

4.5

FUNCTION SELECTIONS

+

0

M

N

20

21

20

Pp

SENSIBILITY

PART. OPEN

CH1

PROGR.

2

1

3

4

5

6

7

8

9 10

ON

315mA

1A

1,6A

7.5A

XS100

PROG

D1

D3

ST

ALIM

L1T

N

D

EXTERNAL LED

D

TX1

T

20

G

TX1

D3

G

D7

G

D6

SW1 = Automatic closure
SW2 = Open/Close/Reverse
SW3 = Open only
SW4 = Preflashing
SW5 = Obstacle detection

SW7 = Reopening during closing
SW8 = Partial stop
SW9 = Function slowing activated
SW10 = Safety test function

SW6 = Manual operation

DIP SWITCH FUNCTION

D6

D7

Remove the board protection, removing
the two screws as shown in the figure.

1 2

3 4

5 6

7 8

9 1

0 11

12 0

2 03

04 0

5 06

V1V

2V3

V4V

5

57ND24-W

004

3 A
MA

LAS

YA

57ND24-W

004

3 A
MA

LAS

YA

57ND24-W

004

3 A
MA

LAS

YA

57ND2

4-W

004

3 A
MA

LAS

YA

57ND

24-W

7WO.022uJ

004

3 A
MA

LAS

YA

1 ON 

Automatic closure;

 

the automatic-clo-

sure timer self-powers at the end of the
opening movement time. The adjustable
pre-set time however depends on the in-
tervention of any safety accessories and it
is cut out after a “stop” intervention or in
the event of a power failure;

2 ON - 3 OFF 

“Open-stop-close-stop” with

pushbutton (G-Ps) and remote control
(radio board inserted);

2 OFF - 3OFF 

“Open-close” with

pushbutton (G-Ps) and remote control
(radio board inserted);

3 ON

 “Open only” with remote control (ra-

dio board inserted);

4 ON 

“Pre-flashing during opening and

closing;

 

after an opening or closing com-

mand, the flashing lamp connected to 20-
K1 flashes for 5 seconds before beginning
the manoeuvre;

+

2

1

3

4

5

6

7

8

9 10

ON

Select the functions by setting the dip
switch to ON or OFF, using a screwdriver
as indicated in the figure.
By default, dip switches 7 and 8 are set to
“ON”.

12

6

3

9

1

2

4

5

7

8

10

11

1"

120"

Summary of Contents for LINESTAR

Page 1: ...AUT AUTOMA OMA OMA OMA OMATION FOR SLIDING GA TION FOR SLIDING GA TION FOR SLIDING GA TION FOR SLIDING GA TION FOR SLIDING GATES TES TES TES TES INSTALLATIONMANUAL LINEST LINEST LINEST LINEST LINESTAR...

Page 2: ...he automation page 4 3 0 Unit assembly page 5 4 0 Description of the control board page 12 4 1 Main components of the control board page 13 4 2 Electric connections page 14 4 3 Check test for photoele...

Page 3: ...57N D24 W 004 3 A MAL ASY A 57N D24 W 004 3 A MAL ASY A 57N D24 W 004 3 A MAL ASY A 57N D24 W 7W O 0 22u J 004 3 A MAL ASY A Gearmotor Transformer Control board Cover Chain fixing brackets Fixing plat...

Page 4: ...ency 48 cycles h with 5 m gate Operative intermittence 50 Reduction ratio 1 50 Operation environment temperature from 20 to 70 C Weight 15 kg 210 mm 290 mm 160 mm 317 mm 104 mm Automation for resident...

Page 5: ...t The underground guide must be well fixed to the ground completely on the sur face along all its length and have no bends kinks to hinder gate movement The upper guide runners must not cause friction...

Page 6: ...n the anchoring bracket and insert it into the cavity The mold box must emerge 50 mm above ground level Insert an iron grating to reinforce the ce ment and consolidate the anchoring bracket Mold box G...

Page 7: ...Position the fixing plate at 55 and 220 mm from the gate when fully open see fig ure Fill the mold box with cement The plate must be perfectly level clean in all its ends with the screw threads fully...

Page 8: ...ers Secure the second bracket from the other end of the gate following the procedures above Secure the chain onto the bracket using the tie rods nuts washers and the hooks supplied Secure the other e...

Page 9: ...D24 W 0043 A MAL ASY A 57N D24 W 0043 A MAL ASY A 57N D24 W 0043 A MAL ASY A 57N D24 W 0043 A MAL ASY A 57N D24 W 7W O 0 22u J 0043 A MAL ASY A Position the gearmotor over the anchor ing bracket with...

Page 10: ...A 57N D24 W 0043 A MAL ASY A 57N D24 W 0043 A MAL ASY A 57N D24 W 7W O 0 22u J 0043 A MAL ASY A Secure the gearmotor unit with the wash ers and nuts to make the unit hitch to the plate in an integral...

Page 11: ...river to remove the end stop unit cover 1 2 3 4 5 6 7 8 9 1011120203040506V1V 2V3 V4V 5 57N D24 W 0043 A MAL ASY A 57N D24 W 0043 A MAL ASY A 57N D24 W 0043 A MAL ASY A 57N D24 W 0043 A MAL ASY A 57N...

Page 12: ...stopped at open position and the automatic closing is excluded to resume the movement you must press the command pushbutton or use the remote control The board has these functions opening closure com...

Page 13: ...ng re opening 13 Terminal board for connecting the motor 14 Terminal board for connecting possible accessories 15 Terminal board for connecting the voltage presence notifying LED 16 Terminal board for...

Page 14: ...0 0 0 1 0 0 0 0 0 1 Ref Des Ref Des 00000 00000 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 00000 1 2 00000 1 2 26 17 0 FA FA FC FC F F FA FC F FA FC F L2T L1T FA FA FC FC F F FA FC F FA FC F L N TX T N M N M FA...

Page 15: ...t the panel is powered with emergency batteries Black Red Blue Flashing lamp 24V 25W signals with the intermittent flashing the gate movement with possibility of pre flashing while opening and closing...

Page 16: ...he pushbutton dip switch 6 in ON G Ps G ST 21 20 1 2 1 TX T G TX N M N M G G Ps Ps G G ST ST 21 21 20 20 20 21 G Ps Pp 1 2 1 2 ST G TX T G TX N M Stop pushbutton N C contact remove the bridge wire It...

Page 17: ...OPEN GR 7 5A TX1 T 20 D3 G D7 G D6 21 20 Tx T 20 G Tx D1 AUTOM CLOSING SENSIBILITY PART OPEN GR 7 5A TX1 T 20 D3 G D7 G D6 Connection of a pair of photoelectric cells in re opening during the closure...

Page 18: ...opening 21 Tx T 20 G Tx D1 AUTOM CLOSING SENSIBILITY PART OPEN OGR 7 5A TX1 T 20 D3 G D7 G D6 Photoelectric cells in partial stop Photoelectric cells in re opening Safety rib in re closing N C contac...

Page 19: ...ain transmitters duplication Clikstar is already coded To add transmitters to the ones supplied follow the following duplication procedure 1 Press the button to code until after 7 of flashing the Red...

Page 20: ...004 3A MA LAS YA 1 ON Automatic closure the automatic clo sure timer self powers at the end of the opening movement time The adjustable pre set time however depends on the in tervention of any safety...

Page 21: ...phase the photoelectric cells cause the direction to reverse until full opening if the device used set the dip switch to ON Opening Closure 8 OFF Partial stop only with connected photoelectric cells...

Page 22: ...Y Sensitivity of the amperometric sensor Adjusts the sensitiv ity of the sensor that constantly checks the force developed by the motor during the opening and closing phases if the pre set level is ex...

Page 23: ...LED ST Comes on every time the total stop button is pressed YELLOW LED D6 Signals the intervention of the rib with gate during close PROG D1 D3 ST ALIM D6 D7 YELLOW LED D1 Signals the pres ence of an...

Page 24: ...N D24 W 7W O 0 22u J 0043 A MAL ASY A BATTERY BATTERY 5 0 MAINTENANCE Periodical checks whether the electric cables are intact wheels guide pads underground guide and the stop blocks see page 5 chain...

Reviews: