background image

Troubleshooting  

[email protected]     www.motorvac.com

5

Problem

Possible Cause

Neither pump will turn on

Ensure shop air is properly connected.
Check internal pressure regulator.

Suction is slower than it used to be

If gear oil is cold it will be very thick and will flow 
slowly.
Check adapter for kinks or other damage.
Use larger adapter whenever possible.
Clean screen filters on control panel.

Parts

Please refer to the part numbers below when ordering parts for this unit. 

Part #   

 

Description

 

 

050-2430 

 

Pump Air Operated

98820975 

 

Ball Valve

98820311 

 

Air Pressure Regulator

200-9031 

 

Adapter Diff-Vac 5/16”

200-9030 

 

Adapter Diff-Vac 1/4”

050-2435 

 

Filter

ORDERING PARTS

Parts for the unit may be ordered by calling MotorVac Customer Service at (800) 841-8810 or  
(905) 615-8620.  Please have your model and serial numbers available.

www.motorvac.com
[email protected]

Summary of Contents for Diff-Vac 1000

Page 1: ...1324 Blundell Rd Mississauga ON Tel 905 615 8620 Fax 905 615 9745 www motorvac com USER MANUAL Diff Vac 1000 Differential Fluid Service System Part No 500 9025...

Page 2: ...ations by exchanging most of the fluid in engine oil pans manual transmissions and differentials Connections to the vehicle are achieved with the supplied adapters Once connected the unit can be safel...

Page 3: ...nfo motorvac com www motorvac com Table of Contents Page Warnings System Features and Functions Controls Initial Setup Initial System Flush Operating Instructions Troubleshooting Parts 1 2 3 4 4 4 5 5...

Page 4: ...lode and cause injury Fluids can leak or escape Use only well ventilated areas Breathing vapors or fluids from leaks can cause illness or injury Pressurized air or fluid stream can propel dust or part...

Page 5: ...kinked or damaged D Adapter Storage Place adapters in holder when not in use The machine can be used to remove fluid from the holder if it becomes full E Control Panel See Controls for details F Clea...

Page 6: ...Controls A Waste Fluid Filter B Pump Selector Valve C Clean Fluid Filter D Hose Selector Valve info motorvac com www motorvac com 3 A B C D...

Page 7: ...position and Pump Selector Valve to CLEAN fluid position 9 Once refilled turn Pump Selector Valve to OFF position Initial Setup 1 Connect appropriate air nipple to air inlet port Use 1 wrench to hold...

Page 8: ...r adapter whenever possible Clean screen filters on control panel Parts Please refer to the part numbers below when ordering parts for this unit Part Description 050 2430 Pump Air Operated 98820975 Ba...

Page 9: ...1324 Blundell Rd Mississauga ON Tel 905 615 8620 Fax 905 615 9745 www motorvac com ZIM13 00872...

Reviews: