Status-Bits EN
P920380 - MIC6
Revision: 33493
General Status 1
19
Schedule A/B
i
Current schedule
0: Schedule A
1: Schedule B
20
Primary Open Detection Enabled
i
During ignition: detection currently enabled
Otherwise: detection supported with the selected coil
21
Primary Short Detection Enabled
i
During ignition: detection currently enabled
Otherwise: detection supported with the selected coil
22
Secondary Open Detection Enabled i
During ignition: detection currently enabled
Otherwise: detection supported with the selected coil
23
Secondary Short Detection Enabled i
During ignition: detection currently enabled
Otherwise: detection supported with the selected coil
24
Secondary Voltage Estimation
Enabled
i
During ignition: estimation currently enabled
Otherwise: estimation supported with the selected coil
25
GPO1
i
Logic state of GPO1
0: Not switched
1: Switched
26
GPO2
i
Logic state of GPO2
0: Not switched
1: Switched
27
GPO3
i
Logic state of GPO3
0: Not switched
1: Switched
28
reserved
-
-
29
GPI1
i
Input level of GPI1
30..
32
reserved
-
-
3
General Status 2
No. Name
K
Description/Comments
1
Warning: Temperature Limit
Exceeded
i
The warning is set if the device temperature exceeds the
limit of 110 °C (230 °F) for 2 minutes.
If the device temperature falls below the threshold, the
warning is automatically reset.
2
Warning: Power Output Limit
Exceeded
i
The warning is set if the power output exceeds the limit of
224 W for 2 minutes.
If the supply voltage is below 17 V this warning occurs
also with lower power output.
If the power output falls below the threshold, the warning
is automatically reset.
3
Warning: Invalid Coil Data Received i
During configuration coil data have been received but
5 / 8