AT Commands
5-38
V.3600
Storing a Configuration — &W
The
&W
commands store the current configuration options in one of two
nonvolatile memory locations (Figure 5-1). The stored configurations
are retained in memory even when power is off, or until
&W
is issued
with a new configuration.
Figure 5-1. Configuration Storage and Recall
Powerup Option Set — &Y
The
&Y
command determines which user option set is loaded during
powerup and reset.
Command
Operation
&W
Store options to user option set 1
&W1
Store options to user option set 2
Command
Operation
&Y
Powerup with user option set 1
&Y1
Powerup with user option set 2
&Y?
Displays currently selected powerup option set