Test Mode Operation
V.3600
7-7
Exiting RDL/TP the modem responds with a three digit value between 0
and 255 representing the number of errors which occurred during test
pattern detection. If errors occur, repeat the test several times to verify
the consistency of the problem, then use the analog loopback tests to
isolate the problem.
Figure 7-5. Local Modem Initiating Remote Digital Loopback
with Test Pattern
Test Pattern — %T
In Test Pattern, transmitted data from the local DTE is blocked and
replaced by a V.52 compatible test pattern. When the modem transmits
the test pattern, it expects to receive the same pattern.
Bilateral Digital Test Enable / Disable — *DG
Enable or disable bilateral test functions.
Command
Operation
*DG
Bilateral digital loop disabled
*DG1
Bilateral digital loop enabled