RFID Preferences
The parameters in this chapter control RFID behavior.
Multifunction Mode Triggering
You can set trigger options for each of the digital scanner’s trigger positions. For example, set Trigger A (pressed
with your index finger) to imager decoding, set Trigger B (pressed with your middle finger) for laser decoding, and
set Trigger A + B (pressed with both fingers) for RFID reading.
The default operation is single trigger, so if you do not assign values to each trigger option (or assign Trigger A
only), Trigger B operates the same as Trigger A, and a dual trigger pull is ignored.
Select one of the following functions for each trigger using the bar codes on the next few pages:
•
Laser Preferred Decoding
- Programs the trigger for decoding using the laser engine first, then the imager
if a decode does not occur. Refer to the
Symbol DS9808 Product Reference Guide
for more information.
DS9808-SR/DL models do not support this option.
•
Imager Decoding
- Programs the trigger for decoding using the imager engine.
•
RFID Reading
- Programs the trigger for reading RFID tags.
•
Imager Plus RFID
- A trigger pull attempts decode using the imager engine, and turns on the optional RFID
reader, if available, to read RFID tags.
•
Laser Preferred Plus RFID
- A trigger pull attempts decode using the laser engine first, then the imager if a
decode does not occur, and also turns on the RFID reader to read RFID tags. DS9808-SR/DL models do not
support this option.
•
Laser Only Decoding
- Programs the trigger for decoding using the laser engine only. DS9808-SR/DL
models do not support this option.
•
Set to Trigger A Value
(Trigger B Only) - Sets Trigger B to the same value as Trigger A. This allows you to
automatically program Trigger B upon selecting the function of Trigger A.
•
Ignore Dual Trigger Pull
(Trigger A+B Only) - Uses the mode of the first trigger pull only. This increases
triggering efficiency when the dual trigger is not needed.
Figure 3-1
Trigger Locations
Trigger A
Trigger B
Summary of Contents for Symbol DS9808-DL00007C1WR
Page 1: ...Symbol DS9808 R Product Reference Guide Supplement ...
Page 2: ......
Page 3: ...Symbol DS9808 R Product Reference Guide Supplement 72E 132822 01 Revision A April 2010 ...
Page 6: ...iv Symbol DS9808 R Product Reference Guide Supplement ...
Page 14: ...xii Symbol DS9808 R Product Reference Guide Supplement ...
Page 20: ...1 6 Symbol DS9808 R Product Reference Guide Supplement ...
Page 39: ...RFID Preferences 3 13 RFID Same Tag Timeout continued 5 Minutes 15h 15 Minutes 1Bh 1 Hour 21h ...
Page 54: ...3 28 Symbol DS9808 R Product Reference Guide Supplement ...
Page 68: ...5 2 Symbol DS9808 R Product Reference Guide Supplement ...
Page 72: ...6 4 Symbol DS9808 R Product Reference Guide Supplement ...
Page 78: ......
Page 79: ......