background image

RFS7000 Series RF Switch

Installation Guide

Summary of Contents for RFS7000 Series

Page 1: ...RFS7000 Series RF Switch Installation Guide ...

Page 2: ...Logo are registered in the US Patent Trademark Office Symbol is a registered trademark of Symbol Technologies Inc All other product or service names are the property of their respective owners Motorola Inc 2007 All rights reserved ...

Page 3: ...1 0 Introduction 1 2 0 Specifications 3 3 0 LED Codes 4 4 0 Hardware Setup 10 5 0 Regulatory Information 20 6 0 Part Numbers Support and Sales 23 7 0 End User License Agreement 25 Contents ...

Page 4: ...the RFS7000 Series RF Switch lets you create multiple WLANs without changing or adding to the existing wired network infrastructure This document is written for the network device installer 1 1 Package Contents Inspect the package contents and report any missing or damaged items to your sales representative The package should contain the following RFS7010 RF Switch with Rack Brackets installed Con...

Page 5: ...e to a power surge or power failure Verify that the power connector and socket are accessible at all times during the operation of the equipment Do not work with power circuits in dimly lit spaces Do not install this equipment or work with its power circuits during thunderstorms or other weather conditions that could cause a power surge Verify there is adequate ventilation around the device and am...

Page 6: ...ing of these circuits Install surge protection Be sure to use a surge protection device between the electricity source and the RFS7000 Series RF Switch Install an Uninterruptible Power Supply UPS A UPS provides continuous power during a power outage Some UPS devices have integral surge protection UPS equipment requires periodic maintenance to ensure reliability A UPS of the proper capacity for the...

Page 7: ...System System Status 1 LED System Status 2 LED Event Off Off Power off Green Blinking Green Blinking Power On Self Test POST running Green Solid Green Blinking POST succeeded Operating System Loading Green Solid Off POST succeeded Normal Operation Amber Blinking Off POST Failure Alternating Green Blinking Amber Blinking Alternating Green Blinking Amber Blinking Boot Up Error Device has an invalid ...

Page 8: ...m Status 2 LED Event Off Off Power off Green Solid Off No Redundancy Feature Enabled Green Blinking Green Solid Redundant System failed over and adopting ports Green Blinking Alternating Green Blinking Amber Blinking Redundant System not failed over Green Solid Amber Blinking No License to adopt Access Ports or No Country Code configured on the switch Fan LED Event Off System Off POST Start Green ...

Page 9: ...cified operating limit Amber Solid Ambient Inlet Temperature is near the maximum operating temperature During switch start up this LED will be lit Solid Amber This is normal behavior and does not indicate an error Amber Blinking Ambient Inlet Temperature is above the maximum specified operating temperature System will be held in reset until the issue is resolved ...

Page 10: ...eed LED Event Off 10 Mbps Green Solid 100 Mbps Green Blinking 1000 Mbps Amber Blinking Port Fault Port Status LED Event Off No Link or Administratively shut down Green Solid Link present Green Blinking Activity Transmit and Receive Amber Blinking Link Fault V PB 3RUW VSHHG 3RUW VWDWXV 3RUW VSHHG 3RUW VWDWXV ...

Page 11: ... 3 2 SFP Port Status LED Port Speed LED Event Green Blinking 1000 Mbps Amber Blinking Module or Tx Rx Fault Loss Port Status LED Event Off No Link or Administratively shut down Green Solid Link present Operational Amber Blinking Module or Tx Rx Fault Loss V PB 3RUW VSHHG 3RUW VWDWXV 8SSHU 3RUW RZHU 3RUW ...

Page 12: ...ed LED 3 5 Out of Band Management Port Status LED Port Speed LED Event Off 10 Mbps Green Solid 100 Mbps Amber Blinking Port Fault Port Status LED Event Off No Link Green Solid Link present Green Blinking Activity Transmit and Receive Amber Blinking Link Fault V PB 3RUW VSHHG 3RUW VWDWXV ...

Page 13: ...e sections that follow describe detailed connection and cabling information for each port For software configuration please see the RFS7000 Series RF Switch System Reference Guide available from the Motorola website V PB LJDELW WKHUQHW 6 3V RQVROH FRQQHFWRU 2XW RI EDQG PDQDJHPHQW SRUW 3RUW RPSDFW ODVK 86 SRUWV LJDELW WKHUQHW 5 V V PB 2XW RI DQG 0DQDJHPHQW LJDELW 6 3 3RUW LJDELW WKHUQHW 3RUW RQVROH...

Page 14: ...four RJ 45 Gigabit Ethernet ports and four Gigabit SFP fiber optic ports Using the RJ 45 ports requires connecting a Category 6 Ethernet cable to the port To use the Gigabit SFP ports first install the SFP Modules Motorola Part Number Fiber 3000 1S WWR LJDELW WKHUQHW 5 V LJDELW WKHUQHW 6 3V ...

Page 15: ...h Installation Guide 12 4 2 1 Installing Gigabit Ethernet SFPs 1 Open the bail on the transceiver 2 Insert each of the SFP transceivers into the corresponding ports on the switch 2SHQ EDLO WR LQVHUW RU UHPRYH 6 3 WUDQVFHLYHU ...

Page 16: ...Hardware Setup 13 3 Once the SFP transceivers are properly seated in their ports close the bails to lock the transceivers in place 4 Insert the fiber optic cables into the installed transceivers ...

Page 17: ...elow to connect the devices to the switch and then access those devices through the Web UI 1 Connect the USB cable to either of the USB ports 2 If applicable connect the USB cable to a USB storage device 3 If applicable power on the USB storage device 4 Follow the instructions in the RFS7000 Series RF Switch System Reference for more information on accessing USB storage devices from the switch 86 ...

Page 18: ... instructions below to connect a Compact Flash Card to the switch and then access that card through the Web UI 1 To use a Compact Flash card with the RFS 7010 insert the card into the Compact Flash slot 2 Once the Compact Flash card has been inserted follow the instructions in the RFS7000 Series RF Switch System Reference to access the Compact Flash card RPSDFW ODVK VORW RPSDFW ODVK ...

Page 19: ...Rack Mount Instructions To install the RFS7000 Series RF Switch in a rack 1 The rack mounting brackets are installed at the factory No additional steps are needed 2 Attach the brackets to the rack using screws appropriate for your rack s mounting holes ...

Page 20: ...tured below connect the RFS7000 Series RF Switch serial port to an RS 232 DB 9 serial port on a separate computer the configuration computer 2 On the configuration computer configure a terminal emulation application such as HyperTerminal as follows Terminal Type VT 100 Port COM port Terminal Settings 19200bps transfer rate 8 data bits no parity 1 stop bit no flow control no hardware compression ...

Page 21: ...Switch 2 Plug the cord into a standard AC outlet with a voltage range of 100 to 240 VAC WARNING An improper shutdown can render the RFS7000 Series RF Switch inoperable such that it could require service by Motorola Support Do not remove AC power without first following the shutdown procedure An abrupt loss of power can corrupt the information stored on the device V PB 5DFN PRXQW EUDFNHW LQOHW ...

Page 22: ... POST test succeeds the System 1 LED will be lit solid green As the software is initialized the System 2 LED will blink green After the software has finished initializing the System 1 LED will be lit solid green and the bottom System 2 LED will be off The RFS7000 Series RF Switch is ready to be configured as described in the RFS7000 Series RF Switch System Reference Other LED codes indicate the pr...

Page 23: ...1 The laser classification is marked on the device Class 1 Laser devices are not considered to be hazardous when used for their intended purpose The following statement is required to comply with US and international regulations Country Selection Select only the country in which you are using the device Any other selection will make the operation of this device illegal Radio Frequency Interference...

Page 24: ...liance Dansk Til kunder i EU Alle produkter skal returneres til Symbol til recirkulering når de er udtjent Læs oplysningerne om returnering af produkter på http www symbol com environmental_compliance Deutsch Für Kunden innerhalb der EU Alle Produkte müssen am Ende ihrer Lebensdauer zum Recycling an Symbol zurückgesandt werden Informationen zur Rücksendung von Produkten finden Sie unter http www s...

Page 25: ...en dienen aan het einde van hun levensduur naar Symbol te worden teruggezonden voor recycling Raadpleeg http www symbol com environmental_compliance voor meer informatie over het terugzenden van producten Português Para clientes da UE todos os produtos no fim de vida devem ser devolvidos à Symbol para reciclagem Para obter informações sobre como devolver o produto visite http www symbol com enviro...

Page 26: ...phone or fax within the time limits set forth in support agreements If you purchased your Enterprise Mobility business product from a Motorola business partner contact that business partner for support Customer Support Web Site Motorola s Support Central Web site located at www symbol com support provides information and online assistance including developer tools software downloads product manual...

Page 27: ...8 5200 in outside North America http www motorola com Product Sales and Product Information North America International Motorola Inc One Symbol Plaza Holtsville New York 11742 1300 Tel 1 631 738 2400 or 1 800 722 6234 Fax 1 631 738 5990 Motorola Inc Symbol Place Winnersh Triangle Berkshire RG41 5TP United Kingdom Tel 0800 328 2424 Inside UK 44 118 945 7529 Outside UK ...

Page 28: ...pt to discover the source code or structure sequence and organization of the Software or iii rent lease or use the Software for timesharing or service bureau purposes or otherwise use the Software for any commercial purpose on behalf of any third party Licensee shall maintain and not remove or obscure any proprietary notices on the Software and shall reproduce such notices exactly on all permitted...

Page 29: ...ot limited to any if any implied warranties or conditions of merchantability of fitness for a particular purpose of lack of viruses of accuracy or completeness of responses of results and of lack of negligence or lack of workmanlike effort all with regard to the Software and the provision of or failure to provide Support Services ALSO THERE IS NO WARRANTY OR CONDITION OF TITLE QUIET ENJOYMENT QUIE...

Page 30: ...ates or foreign agency or authority and Licensee shall not export or allow the export or re export of the Software in violation of any such restrictions laws or regulations By downloading or using the Software Licensee agrees to the foregoing and represents and warrants that Licensee is not located in under the control of or a national or resident of any restricted country 13 MISCELLANEOUS License...

Page 31: ...MOTOROLA INC 1303 E ALGONQUIN ROAD SCHAUMBURG IL 60196 http www motorola com 72E 85979 01 Revision A April 2007 ...